Anritsu 37269B Vector Network Analyzer
Experience cutting-edge performance with the Anritsu 37269B Vector Network Analyzer, engineered for rapid and precise S-parameter measurements of passive devices. Operate efficiently across a broad frequency range from 40 MHz to 40 GHz, making it an essential tool for your testing needs in various applications.
Key Features
- Fast Sweeping Synthesized Source for swift measurements
- Auto Reversing Test Set that minimizes manual intervention
- Solid-State Transfer Switch enhances reliability
- Four Independent Displays providing detailed insights
- Four Channel Receiver allowing comprehensive analysis
- Internal Hard and Floppy Disk Drives for data storage
- LRL/LRM Calibration for increased measurement accuracy
- Adapter Removal Calibrations streamline testing processes
- High Measurement Throughput via GPIB interface
Dynamic Specifications
Frequency (GHz) |
Max. Signal Into Port 2 (dBm) |
Noise Floor (dBm) |
Receiver Dynamic Range (dB) |
Port 1 Power (dBm, Typical) |
System Dynamic Range (dB) |
0.04 |
+20 |
-70 |
90 |
0 |
70 |
2 |
+3 |
-98 |
101 |
0 |
98 |
20 |
+3 |
-95 |
98 |
-5 |
90 |
40 |
+3 |
-93 |
96 |
-15 |
78 |
Measurement Capabilities
- Channels: Four independent measurement channels for flexible testing
- Parameters Measured: S11, S21, S22, S12 and user-defined combinations
- Measurement Frequency Range: Configurable within the calibration range, supporting CW and discrete frequency measurements
- Measurement Domains: Frequency Domain, CW Draw, and optional High-Speed Time (Distance) Domain
- Display Formats: Supports a variety of formats including Log Magnitude, Smith Chart, Group Delay, and more
- Maximum Data Points: 1601 data points can be utilized without recalibration, with arbitrary frequency points also supported
- Reference Delay Correction: Automatic compensation for different transmission media, ensuring accuracy
- Markers: Six independent markers for detailed data analysis
Advanced Features
- Enhanced Marker Search capabilities and marker sweeps for optimized testing
- Limit Lines for PASS/FAIL testing, with clear results on CRT
- Tune Mode designed for tuning applications, optimizing measurement speed effectively
- Data segmentation and limit capabilities allow for robust testing environments
Measurement Times
Typical Measurement Times vs. Data Points
Calibration Type/Data Points |
Time (ms) |
1 Port (3 Term) / 3 Points |
60 |
Full 2 Port / 3 Points |
60 |
1 Port (3 Term) / 1601 Points |
3300 |
Full 2 Port / 1601 Points |
3600 |