Avante Waveline Touch Patient Monitor with Touch-Screen

Do you have a Avante Waveline Touch Patient Monitor with Touch-Screen you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Avante

Category: Avante

Avante Avante Waveline Touch Patient Monitor with Touch-Screen
Avante Avante Waveline Touch Patient Monitor with Touch-Screen
Avante Avante Waveline Touch Patient Monitor with Touch-Screen
Avante None - Avante
Avante None - Avante
Avante None - Avante

Avante Waveline Touch Patient Monitor with Touch-Screen


The Avante Waveline Touch Patient Monitor is a state-of-the-art medical device designed to enhance patient care with its user-friendly features and comprehensive monitoring capabilities. Equipped with a vibrant 12.1" color TFT display, this touch-screen monitor offers intuitive navigation and clarity, making it easier for healthcare professionals to access critical patient data at a glance.
This multifunctional patient monitor tracks essential vital signs, including ECG, SpO2, NIBP, heart rate, temperature, and respiration. It also provides advanced features such as multi-lead ECG monitoring and ST segment analysis, along with the ability to review up to 72 hours of trend data for informed decision-making.

Key Features:

  • Enhanced User Interface: A larger timestamp and standby button improve usability.
  • Audible Alerts: Revised SpO2 pitch tones alert caregivers to changes without being intrusive.
  • Customizable Preferences: Adjust volume and sound settings as needed, with options to turn them off entirely.
  • Data Printing Options: Easily print numerical data only when required, streamlining documentation.
  • Waveform Customization: Change the color of waveforms to meet individual preferences.
  • Compliance Features: The EtCO2 option ensures adherence to ASA standards.
  • Invasive Monitoring Options: Add dual invasive blood pressure monitoring for comprehensive assessment.
  • Portability: The built-in battery option enhances mobility, allowing for flexible patient monitoring.
  • Advanced Display: View OxyCRG and NIBP details clearly with a sophisticated, dynamic layout.
  • Network Capable: Connect seamlessly to a central monitoring system via wired or wireless networks.
  • User-Friendly Design: Compact and lightweight, perfect for both stationary and mobile use.
  • Multilingual Capabilities: Accommodate diverse user needs with multi-lingual settings.
  • Integrated Recording: The built-in thermal recorder captures vital data effectively.
  • Drug Dose Calculations: Simplify medication management and improve patient safety.

The Avante Waveline Touch Patient Monitor stands out with its fusion of modern technology, compact design, and comprehensive features, making it an ideal choice for healthcare environments focused on delivering superior patient care.

Avante Waveline Touch Patient Monitor - Specifications


Physical Weight & Dimensions

  • Weight: 5 kg (11 lbs)
  • Height: ~28 cm (11 inches)
  • Depth: ~15.7 cm (6.2 inches)
  • Width: ~32 cm (12.6 inches)

Application

  • Suitable for neonatal, pediatric, and adult patients.

Operating Environment

  • Power Source: External AC power or internal rechargeable battery.
  • AC Power: 100-240 VAC, 50/60 Hz, <150 VA.
  • Battery: Rechargeable Lead-Acid; Operating time under normal conditions: 1 hour; Operating time after first low battery alarm: 10 minutes.

Temperature

  • Working Temperature: 5°C - 40°C (41°F - 104°F)
  • Storage Temperature: -20°C (-4°F)

Performance Specifications

  • Display: 12.1" color TFT, Touch Screen.
  • Resolution: 800 × 600 pixels.
  • Trace: 4, 6, or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2.
  • Indicators: Alarm indicator; Power indicator; QRS beep and alarm sound.
  • Trend Time: 72 hours.
  • Recorder: Built-in thermal array, 2 channels; Record Width: 48 mm (1.89 in); Recorder Paper: 50 mm (1.97 in); Record Speed: 25 mm/s (1 in/s), 50 mm/s (2 in/s).

ECG

  • Input: 3-lead ECG cable and standard AAMI line; Optional 5-lead ECG cable.
  • Lead Choice: I, II, III, aVR, aVF, aVL, V.
  • Gain Choice: x0.5, x1.0, x2.0.
  • Frequency Characteristic: 0.05 - 40 Hz.
  • ECG Waveforms: 7 channels.
  • Penetration Voltage: 4000 VAC 50/60 Hz.
  • Sweep Speed: 12.5, 25, and 50 mm/s.
  • HR Display Range: 30 - 300 bpm.
  • Accuracy: ±1% or ±1 bpm, whichever is greater.
  • Alarm Limit Range Setting: Upper limit 80 - 400 bpm; Lower limit 20 - 150 bpm.

RESP

  • Measurement Method: RA-LL impedance.
  • Range: 0 - 120 rpm.
  • Accuracy: ±3 rpm.
  • Alarm Upper-Lower Limit Setting: Upper limit 6 - 120 rpm; Lower limit 3 - 120 rpm.
  • Sweep Speed: 12.5 and 25 mm/s.

NIBP (Suntech)

  • Measuring Technology: Automatic oscillating measurement.
  • Cuff Inflating: <30s - 0-300 mmHg, standard adult cuff.
  • Measuring Period: AVE < 40s.
  • Mode: Manual, Auto, STAT.
  • Measuring Interval in AUTO Mode: 2 min - 4 hrs.
  • Pulse Rate Range: 30 - 250 bpm.
  • Measuring Range:
  • Adult/Pediatric Mode: SYS 40 - 250 mmHg, DIA 15 - 200 mmHg;
  • Neonatal Mode: SYS 40 - 135 mmHg, DIA 15 - 100 mmHg.
  • Resolution: 1 mmHg.
  • Accuracy: Pressure, Maximum Mean Error ±5 mmHg, Max. Standard Deviation 8 mmHg.
  • Overpressure Protection: Adult Mode 280 mmHg, Neonatal Mode 150 mmHg.
  • Alarm Limit Setting: SYS 50 - 240 mmHg, DIA 15 - 180 mmHg.

TEMP

  • Range: 25°C - 50°C (77°F - 122°F).
  • Accuracy:
  • ±0.2°C at 25.0°C - 34.9°C;
  • ±0.1°C at 35.0°C - 39.9°C;
  • ±0.2°C at 40.0°C - 44.9°C;
  • ±0.3°C at 45.0°C - 50.0°C.
  • Display Resolution: 0.1°C.
  • Alarm Upper-Lower Limit Setting: Upper Limit 0 - 50°C, Lower Limit 0 - 50°C.
  • Channels: 2.
  • Alarm Limit Setting: 10 - 50°C.

Masimo SET SpO2

  • SpO2 Accuracy (non-motion):
  • Adult Pediatric: 70-100 %: ±2 %, 0-69%: unspecified.
  • Neonate: 70-100 %: ±3 %, 0-69 %: unspecified.
  • SpO2 Accuracy (motion):
  • Adult Pediatric: 70-100 %: ±3 %, 0-69%: unspecified.
  • Neonate: 70-100 %: ±3 %, 0-69 %: unspecified.
  • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5.
  • SpO2: ±2 %; PR: ±3 bpm.
  • Modes: Averaging mode: 2, 4, 8, 10, 12, 14, and 16 s.
  • Sensitivity: Normal, APOD, and Maximum.
  • PR Accuracy (non-motion): Neonate: 70-100 %: ±3 %, 0-69 % : unspecified; Adult Pediatric Neonate: 25-240 bpm: ±3 bpm.
  • PR Accuracy (motion): Adult Pediatric Neonate: 25-240 bpm: ±5 bpm.
  • Measuring Range: SpO2: 1-100 %; PR: 25-240 bpm; Perfusion: 0.02-20 %.

IBP (Option)

  • Measurement Range: -10 - 300 mmHg.
  • Channels: 2.
  • Pressure Transducer Sensitivity: 5 µV/V/mmHg.
  • Impedance Range: 300 - 3000 ?.
  • Transducer Sites: ART, PA, CVP, RAP, LAP, ICP.
  • Resolution: 1 mmHg.
  • Accuracy: ±1 mmHg or ±2%, whichever is greater.
  • Alarm Range: -10 - 300 mmHg.

EtCO2 (Option)

  • Compliance: ASA Standards for Basic Anesthetic Monitoring.
  • Mode of Sampling: Sidestream.
  • Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts.
  • CO2 Measurement Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa).
  • CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated).
  • CO2 Resolution: 0.1 mmHg (0-69 mmHg); 0.25 mmHg (70-150 mmHg).
  • CO2 Accuracy:
  • 0-40 mmHg: ±2 mmHg;
  • 41-70 mmHg: ±5% of reading;
  • 71-100 mmHg: ±8% of reading;
  • 101-150 mmHg: ±10% of reading;
  • Above 80 breaths/min: ±12% of reading.
  • Sampling Rate: 100 Hz.
  • Respiration Rate: 2-150 bpm.
  • Respiration Rate Accuracy: ±1 breath.
  • Response Time: <3 seconds (includes transport time and rise time).
  • Inspired CO2 Measurement Range: 3-50 mmHg.

How can we help you with today?