Chroma 62015B-15-90 DC Power Supply Module
RENT CHROMA 62015B-15-90 (call for availability)
The Chroma 62015B-15-90 DC Power Supply Module is meticulously engineered for a variety of burn-in applications including LCD panels, DC-DC converters, power inverters, notebook computers, battery chargers, and a host of other electronic devices. Its exceptional high power density and low current ripple provide a cost-effective solution for rigorous power testing requirements. Furthermore, its advanced power factor correction circuitry is designed to comply with IEC standards, ensuring reliable and efficient performance.
Key Features:
- Hot-Swappable Maintenance
- Ideal for Burn-in and Plating Applications
- High Power Applications with CSU
- Remote Sense Capabilities
- Remote ON/OFF Functionality
- CAN Bus Control Interface
- Current Range: Up to 2000A (System)
- Power Range: Up to 1.5KW per module, up to 120KW per system
- High Power Density: 464 mW/cm³ (7.13 W/in³)
Specifications:
- Electrical Specifications:
- Output Ratings:
- Programming Accuracy: 1% FS
- Measurement Accuracy: 1% FS
- Output Noise (20MHz):
- Voltage Noise (P-P): 100mV
- Voltage Ripple (rms): 30mV
- Current Ripple (rms): 0.9A
- Efficiency: > 87% @ full load
- Turn On Overshoot Voltage (Rise Time of 100ms): 5% of nominal output
- Transient Response Time: < 5 ms
- AC Input Voltage:
- Six Position Mainframe: 187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) / 45 ~ 65 Hz
- Three Position Mainframe: 187 to 250 Vac (single phase) / 45 ~ 65 Hz
- Input Power Factor: > 0.98 @ full load
- Protection Functions:
- OVP: Automatically shuts down at 115% of set value
- OCP: Current limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
- OTP: Automatically shuts down if internal limit is reached
- I/O Signal:
- Remote ON/OFF (I/P): Dry contact (closed = enabled), vice versa
- AUX Voltage: 4 ~ 24V / 0.5A at mainframe (by trimmer adjust voltage)
- DC OK Signal Type (O/P): Dry contact (closed = enabled) (Error: OVP / OCP / OTP / AC Fault)
- Programming Response Time (Six Position Mainframe through CAN):
- Rise Time (Full Load): For a programmed 5% to 95% step in output voltage: 100ms
- Rise Time (No Load): For a programmed 5% to 95% step in output voltage: 100ms
- Fall Time (Full Load): For a programmed 95% to 5% step in output voltage: 40ms
- Fall Time (No Load): For a programmed 95% to 5% step in output voltage: 5s
- Vout Setting: CAN Bus send command to DC module receiver: 1s
- Measurement V & I: Under CAN command using fetch: 100ms
- Delay Time: For output ON/OFF enable and disable (under CAN command): 5s (Single Mainframe)
- General Specifications:
- Remote Sensing: 3V maximum line loss compensation
- Parallel Operation: Current Sharing (±5%)
- Operating Temperature: 0 ~ 50°C
- Humidity Range: 0 ~ 90% RH, Non-condensing
- Remote Interface: CAN Bus (optional)