Chroma 62015B-80-18 DC Power Supply Module, 80V, 18A, 1440W

Do you have a Chroma 62015B-80-18 DC Power Supply Module, 80V, 18A, 1440W you want to sell?

We buy used equipment! Learn about selling

Image Coming Soon

Chroma 62015B-80-18 DC Power Supply Module

RENT CHROMA 62015B-80-18 (call for availability)

The Chroma 62015B-80-18 DC Power Supply Module is a powerful solution tailored for demanding burn-in applications including LCD panels, DC-DC converters, power inverters, notebook computers, and battery chargers. With its exceptional power density and minimal current ripple, this module provides a cost-effective option for various electronic devices. Equipped with modern power factor correction circuitry, it adheres to IEC standards for enhanced reliability.

Key Features

    • N+1 Redundancy
    • Hot-Swappable Maintenance
    • Ideal for Burn-in and Plating
    • High Power Applications with CSU
    • Remote Sense
    • Remote ON / OFF
    • CAN Bus Control
    • DC OK Signal Output
    • Voltage range: 1 ~ 80V
    • Current range: Up to 2000A (System)
    • Power range up to 1.5KW per module, up to 120KW per system
    • High Power Density: 464 mW/cm3 (7.13 W/In3)

Specifications

Electrical Specifications:

  • Output Ratings:
      • Output Power: 1440W
      • Output Voltage: 1~80V
      • Output Current: 1~18A
    • Line Regulation: 0.1% FS
    • Load Regulation: 1% FS
    • Programming Accuracy: 1% FS
    • Measurement Accuracy: 1% FS
  • Output Noise (20MHz):
      • Voltage Noise (P-P): 200mV
      • Voltage Ripple (rms): 50mV
      • Current Ripple (rms): 0.18A
    • Efficiency: > 88% @ full load
    • Turn On Over Shoot Voltage: 5% of nominal output (Rise Time of 100ms)
    • Transient Response Time: < 5 ms
  • AC Input Voltage:
      • Six Position Mainframe: 187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection)/ 45 ~ 65 Hz
      • Three Position Mainframe: 187 to 250 Vac (single phase) / 45 ~ 65 Hz
      • Input Power Factor: > 0.98 @ full load

Protection Functions:

    • OVP: Automatically shuts down at 115% of set value
    • Adjustment Range: 1~83V
    • OCP: Current limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
    • OTP: Automatically shuts down if internal limit is reached

I/O Signal:

    • Remote ON/OFF (I/P): Dry contact (closed = enabled)
    • AUX Voltage: 4 ~ 24V / 0.5A at mainframe (adjustable voltage)
    • DC OK Signal Type (O/P): Dry contact (closed = enabled) (Error: OVP / OCP / OTP / AC Fault)

Programming Response Time:

    • Rise Time (Full Load): 100ms for a programmed 5% to 95% step in output voltage
    • Fall Time (Full Load): 40ms for a programmed 95% to 5% step in output voltage

General Specifications:

    • Remote Sensing: 3V maximum line loss compensation
    • Parallel Operation: Current Sharing (±5%)
    • Operating Temperature: 0 ~ 50°C
    • Humidity Range: 0 ~ 90% RH, Non-condensing
    • Remote Interface: CAN Bus (optional)
    • Safety & EMC: CE

How can we help you with today?