Chroma 62015B-80-18 DC Power Supply Module
RENT CHROMA 62015B-80-18 (call for availability)
The Chroma 62015B-80-18 DC Power Supply Module is a powerful solution tailored for demanding burn-in applications including LCD panels, DC-DC converters, power inverters, notebook computers, and battery chargers. With its exceptional power density and minimal current ripple, this module provides a cost-effective option for various electronic devices. Equipped with modern power factor correction circuitry, it adheres to IEC standards for enhanced reliability.
Key Features
- Hot-Swappable Maintenance
- Ideal for Burn-in and Plating
- High Power Applications with CSU
- Current range: Up to 2000A (System)
- Power range up to 1.5KW per module, up to 120KW per system
- High Power Density: 464 mW/cm3 (7.13 W/In3)
Specifications
Electrical Specifications:
- Output Ratings:
- Programming Accuracy: 1% FS
- Measurement Accuracy: 1% FS
- Output Noise (20MHz):
- Voltage Noise (P-P): 200mV
- Voltage Ripple (rms): 50mV
- Current Ripple (rms): 0.18A
- Efficiency: > 88% @ full load
- Turn On Over Shoot Voltage: 5% of nominal output (Rise Time of 100ms)
- Transient Response Time: < 5 ms
- AC Input Voltage:
- Six Position Mainframe: 187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection)/ 45 ~ 65 Hz
- Three Position Mainframe: 187 to 250 Vac (single phase) / 45 ~ 65 Hz
- Input Power Factor: > 0.98 @ full load
Protection Functions:
- OVP: Automatically shuts down at 115% of set value
- OCP: Current limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
- OTP: Automatically shuts down if internal limit is reached
I/O Signal:
- Remote ON/OFF (I/P): Dry contact (closed = enabled)
- AUX Voltage: 4 ~ 24V / 0.5A at mainframe (adjustable voltage)
- DC OK Signal Type (O/P): Dry contact (closed = enabled) (Error: OVP / OCP / OTP / AC Fault)
Programming Response Time:
- Rise Time (Full Load): 100ms for a programmed 5% to 95% step in output voltage
- Fall Time (Full Load): 40ms for a programmed 95% to 5% step in output voltage
General Specifications:
- Remote Sensing: 3V maximum line loss compensation
- Parallel Operation: Current Sharing (±5%)
- Operating Temperature: 0 ~ 50°C
- Humidity Range: 0 ~ 90% RH, Non-condensing
- Remote Interface: CAN Bus (optional)