Drager Evita 2 Ventilator

Do you have a Drager Evita 2 Ventilator you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Drager

Category: Respiratory Ventilators

Drager Drager Evita 2 Ventilator
Dräger Evita 2 Ventilator: Excellence in Critical Care Ventilation
The Dräger Evita 2 ventilator is engineered to uphold exceptional standards in ventilation therapy, making it an indispensable asset in critical care settings. Designed with a focus on patient-centric features, this ventilator offers a variety of modes to cater to diverse patient needs, from neonates to adults.
Spontaneous Breathing Strategy
At the heart of the Evita 2's design is the innovative "Room to Breathe" concept. This approach fosters spontaneous breathing, effectively minimizing the risk of atelectasis and optimizing the ventilation/perfusion ratio. The BIPAPTM*/PCV+ mode enhances patient autonomy, allowing for spontaneous breaths at any moment. Additionally, the AutoFlow® function encourages natural breathing patterns across all volume modes, while the Automatic Tube Compensation (ATC) provides a seamless experience for patients with tracheal tubes.
Versatile Patient Compatibility
The Evita 2 excels as a reliable solution for ventilating patients of all ages, thus serving as a vital resource in daily clinical routines. Its adaptability reduces the need for extensive staff training and enhances the flexibility of care delivery.
Two-in-One Ventilation Solution
Combining both invasive and non-invasive ventilation, the Evita 2 aids in weaning patients away from intubation, effectively lowering the reintubation rates. This versatility ensures that ICUs can operate efficiently with just one device for various ventilation needs.
Comprehensive Patient Monitoring
Experience unparalleled oversight with the Evita 2’s high-resolution full-color display, which provides a clear overview of patient conditions and ventilator status. The customizable screen layout allows healthcare professionals to focus on critical parameters—showcasing two ventilation curves and six monitored values simultaneously.
User-Friendly Interface
The ventilator features a streamlined front panel with an intuitive rotary knob for simplified setting adjustments. The "select-adjust-confirm" principle empowers users to modify parameters easily, ensuring rapid response in time-sensitive situations.
Efficiency in Standard Procedures
Designed to enhance operational efficiency, the Evita 2 includes multiple functionalities that accelerate routine tasks. Pre-configured start-up settings tailored to ICU practices facilitate a swift transition to patient ventilation. The suction process is simplified with the push of a button, and the device supports quick maintenance with easy exhalation valve changes. Automatic daily calibration of sensors further streamlines operation, though manual calibration can be performed without interrupting ventilation.
In summary, the Dräger Evita 2 ventilator sets a benchmark for critical care ventilation, blending advanced technology with user-friendly features to deliver optimal patient care. Its robust capabilities ensure both healthcare providers and patients experience enhanced comfort and efficiency in critical situations.

Drager Evita 2 Ventilator Specifications


Physical Weight & Dimensions
  • Height: 11.4 inches (290 mm)
  • Width: 20.9 inches (530 mm)
  • Depth: 17.7 inches (450 mm)
  • Weight: Approx. 27 kg (60 lbs)
  • Diagonal Screen Size: 6.5 inches (TFT LCD color display)

Ventilation Settings
  • Ventilation Modes:
  • IPPV, IPPVAssist (CMV, CMVAssist)
  • SIMV, SIMVASB (SIMV, SIMV/Psupp)
  • MMV, MMVASB (MMV, MMV/Psupp)
  • BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist)
  • CPAP, CPAPASB (CPAP, CPAP/Psupp)
  • APRV (optional)
  • ILV (optional)
  • Enhancements:
  • AutoFlow™: Automatic adaptation of inspiratory flow in volume-controlled modes
  • ATC™: Automatic Tube Compensation (optional)
  • IV: Mask Ventilation (optional)
  • Ventilation Frequency (f): 0 to 100 /min (Neonatal: 0 to 150 /min)
  • Inspiration Time (Tinsp): 0.1 to 10 s
  • Tidal Volume (VT) (BTPS):
  • Adult: 0.1 to 2.0 L
  • Pediatric: 0.02 to 0.3 L
  • Neonatal: 0.003 to 0.1 L
  • Inspiratory Flow:
  • Adult: 6 to 120 L/min
  • Pediatric and Neonatal: 6 to 30 L/min
  • Inspiratory Pressure: 0 to 80 mbar (cmH2O)
  • PEEP / Intermittent PEEP: 0 to 35 mbar (cmH2O)
  • Pressure Assist (PASB) (Psupp): 0 to 80 mbar (cmH2O)
  • Rise Time for Inspiratory Pressure: 0 to 2 s
  • O2 Concentration: 21 to 100 Vol.%
  • Multi-sense Trigger Criteria: Internal automatic pressure trigger, Flow, Volume (Flow adjustable 0.3 to 15 L/min)

Measured Values Displayed
  • Airway Pressure: Peak, Plateau, Mean Pressure, PEEP, Min. Pressure (0 to 99 mbar/cmH2O)
  • Minute Volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
  • Tidal Volume (VT), (BTPS): Inspired VT, Expired VT, VTASB (VTPS) (0 to 3999 mL)
  • Breathing Frequency (f): ftotal, fspon, fmand. (0 to 300 bpm)
  • O2 Concentration: (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
  • Lung Mechanics:
  • Resistance: (0.0 to 600 mbar/L/s)(cmH2O/L/s)
  • Compliance: (0.0 to 300 mL/mbar)(mL/cmH2O)
  • Breathing Gas Temperature: 18°C to 51°C

Alarms / Monitoring
  • Airway Pressure: High/Low
  • Expired Minute Volume: High/Low
  • Tidal Volume: High
  • Apnea Alarm Time: 5 to 60 s
  • Spontaneous Breath Frequency: High
  • Inspired O2 Concentration: High/Low
  • Breathing Gas Temperature: High
  • SpO2 Pulse (optional): High/Low
  • etCO2 (optional): High/Low

Performance Data
  • Max. Flow for Pressure Support and Spontaneous Breathing: 180 L/min (adult), 60 L/min (pediatric)
  • Valve Response Time: ? 5 ms
  • Control Principle: Time cycled, volume constant, pressure-controlled
  • Safety Relief Valve: 100 mbar (cmH2O)
  • Leakage Compensation: Yes
  • Hose System Compensation: Yes
  • Outlet for Pneumatic Nebulizer: Yes

Operating Data
  • Mains Power Connection: 100 to 240 V, 50/60 Hz, 10 to 30 V DC (optional)
  • Power Consumption: Approx. 125 W
  • Gas Supply Operating Pressure: O2, Air: 2.7 to 6 bar / 39 to 87 PSI

Machine Outputs
  • Digital Output: Output and reception via RS 232 C interface
  • Digital Output (Optional): For output and reception via two RS 232 C interfaces
  • Analog Output (Optional): For analog output of two measured values

How can we help you with today?

RECENTLY VIEWED