DRE Spectra AG5 Anesthesia Gas Monitor

Do you have a DRE Spectra AG5 Anesthesia Gas Monitor you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Avante

Category: Monitors - Anesthesia

Avante DRE Spectra AG5 Anesthesia Gas Monitor
Avante DRE Spectra AG5 Anesthesia Gas Monitor
Avante None - Monitors - Anesthesia
Avante None - Monitors - Anesthesia
DRE Spectra AG5 Anesthesia Gas Monitor
  • Dual Functionality for Optimal Patient Care

The DRE Spectra AG5 is a cutting-edge medical device designed to enhance patient monitoring during anesthesia. This innovative product seamlessly combines the functionalities of a multiparameter patient monitor with an advanced anesthetic agent monitor, making it an indispensable tool in any clinical setting.
Key Features:
  • High-Definition Display: The monitor features a large 12.2" diagonal electroluminescent flat panel display, providing clear and vibrant visuals for real-time patient data.
  • Versatile Configurations: Available in various configurations, including base unit, strip-chart recorder, ECG, SpO2, NIBP, CO2, and temperature options, tailored to meet the specific needs of your medical facility.
  • Comprehensive Monitoring: Supports up to 10-channel selectable waveform displays, ensuring comprehensive monitoring capabilities from adult to neonate patients.
  • User-Friendly Interface: The easy-to-follow menu simplifies navigation and use, while programmable audible and visual alarm limits enhance patient safety.
  • Advanced Recording Features: Equipped with a built-in recorder providing up to 96 hours of trend information and 5 minutes of real-time waveform history for effective monitoring and review.
  • Memory and Recall Functionality: Store and recall digital readouts of up to 250 patient readings, making it easy to access historical data.
  • Powerful Operation: Designed for both AC and DC operation, the monitor includes a 2-hour battery backup for continued functionality in any situation.
  • Breath Monitoring: Integrated impedance respiration support and standard monitoring for ECG, EtCO2, N2O, oxygen saturation, NIBP, temperature, and respiration.

Elevate your patient care with the DRE Spectra AG5 Anesthesia Gas Monitor, where advanced technology meets practical functionality, ensuring that healthcare providers can deliver the highest level of care.

DRE Spectra AG5 Anesthesia Gas Monitor Specifications


Physical Weight & Dimensions

  • Height: 12 inches (30.5 cm)
  • Width: 14 inches (35.6 cm)
  • Depth: 7 inches (17.8 cm)
  • Weight: 16 lbs (7.3 kg) / 18 lbs (8.2 kg) with full options

Power Requirements

  • Operation: AC/DC
  • Internal Battery: 2x6 V 3.3 AH sealed lead-acid
  • Battery Life: 2 hours
  • Battery Charge Time: 16-20 hours
  • AC Mains Input: Universal switching power supply, hospital grade plug, 100-250 V / 50-60Hz, 16 VDC / 2.8 A output, UL, CSA, GS

General Features

  • Freeze Buffer: 5 minutes
  • Trends: 6 minutes to 96 hours
  • Alarms: Audio & Visual, user adjustable upper and lower alarm limits
  • Alarm Frequency: Low alarm - 2.0-2.4 KHz; High alarm - 3.0-3.4 KHz

ECG

  • CMRR: 100 dB @ 60 Hz
  • Heart Rate Range: 30-240 bpm
  • Heart Rate Averaging: 4 beat average
  • Heart Rate Accuracy: ±5 bpm or 10%, whichever is greater
  • Response Time of Heart Rate Meter: 80-40 bpm less than 7 sec
  • Change in Heart Rate: 80-120 bpm less than 11 sec
  • Pacemaker Pulse Amplitude: ±2 mV to ±700 mV
  • Rejection Duration: 0.1 ms to 2.0 ms
  • Input: 5-lead ECG/respiration patient cable with no series resistance
  • Lead Selection: I, II, III (standard configuration)
  • ECG Reference Signal: 1 mV software generated
  • Patient Isolation: 5000 VRMS 60 seconds at 60 Hz

Leakage Current

  • Internal to Ground: <0.01 mA (<10 mA)
  • Enclosure: <0.01 mA (<10 mA)
  • Leads-Off Sensing Current:
  • AC current <0.01 mA (<100 mA)
  • DC current <0.01 mA (<10 mA)

Frequency Response/Band Width: 0.5-40 Hz (±dB)

  • Patient Drive Current: <10 mA
  • Maximum T Wave Rejection Capability: 120% of QRS segment
  • Defibrillator & ESIS Protected: Tested with 5 kV
  • Recovery Time Following Defib: Within 8 seconds
  • Lead Fault Alarm: Audible, visual
  • QRS Indicator: Audible: user volume control; Asystole: audible and visual
  • Gain Selection: 0.2 mV, 0.5 mV, 1 mV, 2 mV, 5 mV
  • Aspect Ratio: 0.24, 0.4, 0.6, ±0.8 sec/mV
  • ECG Input Impedance: >2.5 M Ohm

ETCO2

  • Type: Side stream, non-dispersive infrared
  • Method: CO2 sample line with nasal cannula or endotracheal tube connector

Invasive Pressure

  • Channels: Two
  • Measurement Range: -30 to +300 mmHg (-4.0 to +40.0 kPa)
  • Gain Accuracy: ±1% or ±2 mmHg, whichever is greater (±0.27 kPa)
  • Analysis Values: Max., min., and mean pressure; Pulse rate from arterial waveforms
  • Heart Rate Range: 10-250 bpm
  • Heart Rate Accuracy: ±1% or ±5 bpm
  • Transducer Sensitivity: 5 mV/V/mmHg
  • Transducer Excitation: 5V DC
  • Transducer Zero Adjust: ±150 mmHg (±19.99 kPa)
  • Display: Digital waveform display with semi-automatic and manual pressure range scaling. Trend display of pressure waveforms.

Non-Invasive Blood Pressure

  • Method: Automatic oscillometric
  • Parameters Measured: Systolic, diastolic, mean arterial pressure, pulse
  • Scale: mmHg or kPa
  • Operating Modes: Manual, Automatic, Stat
  • Repeat Cycles: 10-50 sec., 1-99 minutes
  • Rapid Cycle Update: 1-4 minutes (STAT mode)

#

Measurement Range

  • Systolic:
  • Adult/Pediatric: 30-250 mmHg (4.0-33.3 kPa)
  • Neonate: 20-160 mmHg (2.7-21.3 kPa)
  • Diastolic:
  • Adult/Pediatric: 10-180 mmHg (1.3-24.0 kPa)
  • Neonate: 10-140 mmHg (1.3-18.7 kPa)

#

Measurement Time

  • Typical: 50 sec, Max: 120 sec
  • Typical Stat: 30 sec
  • Cuff Inflation Rate: Not greater than 40-50 mmHg/sec (5.33-6.66 kPa/sec)
  • Cuff Inflation Pressure: 30 mmHg above last systolic (4.0 kPa)

#

Cuff Pressure Range

  • Adult/Pediatric: 0-250 mmHg (0-33.3 kPa)
  • Neonate: 0-140 mmHg (0-18.7 kPa)

#

Initial Cuff Inflation

  • Adult/Pediatric: 170 ± 10 mmHg (22.7 ± 1.3 kPa)
  • Neonate: 120 ± 10 mmHg (16 ± 1.3 kPa)

#

Auto Deflate Pressure

  • Adult/Pediatric: 280 ± 5 mmHg (36.7-38 kPa)
  • Neonate: 235 ± 5 mmHg (30.7-32.0 kPa)

#

NIBP Alarm Limits

  • Systolic:
  • Upper: 0-255 mmHg (0-34.0 kPa)
  • Lower: 0-254 mmHg (0-33.9 kPa)
  • Diastolic:
  • Upper: 0-255 mmHg (0-34.0 kPa)
  • Lower: 0-254 mmHg (0-33.9 kPa)
  • Mean:
  • Upper: 0-255 mmHg (0-34.0 kPa)
  • Lower: 0-254 mmHg (0-33.9 kPa)

Temperature

  • Temp Scale: °F or °C
  • Temp Range: 82.4-109.8°F (28.0-43.2°C)
  • Temp Accuracy: ±0.2°F (±0.1°C)
  • DTemp Range: 0-27°F (0-15°C)

#

Temp Alarm Limits

  • Upper: 83.0-110.0°F (28.3-43.3°C)
  • Lower: 83.0-109.9°F (28.3-43.2°C)

Recorder

  • Type: Built-in multi-channel thermal array recorder
  • Dot Density: 203 DPI
  • Paper Width: 58 mm
  • Printing Width: 48 mm
  • Speed: 25 mm/sec

How can we help you with today?