RENT Haefely PCD300 (call for availability)
The Haefely PCD300 CDN is a sophisticated coupling and decoupling network that is part of the renowned PSURGE 8000 system. Designed specifically to meet IEC and EN standards, it enables the testing of 3-phase AC and DC power ports efficiently. The PCD300 adheres to vital recommendations for coupling and decoupling component values, predominantly based on European models for AC power lines. With automatic coupling path switching, the PCD300 ensures compliance with all crucial IEC and EN requirements while enhancing the safety of users through its specially designed 4mm connectors that accommodate high voltage impulses.
Key Features:
- Three high voltage inputs for better testing flexibility.
- Combination wave specifications of 1.2/50µs and 8/20µs.
- Capable of producing a 100kHz ring wave for diverse testing scenarios.
- Handles impulse voltages of up to 8kV with ease.
- Supports line voltages of 690Vac phase-to-phase.
- Accommodates EUT current levels up to 32A per phase.
- Phase angle synchronization for precise coupling path management.
Highlights:
- International application: Meets and exceeds the stringent requirements of IEC, EN, and ANSI tests, making it ideal for global usage.
- Synchronization path switching: The PCD300 synchronizes impulses effectively with the selected coupling path, ensuring precision in testing.
- 32A capability: Supports DC loads up to 32A per phase and AC loads up to 28A, providing versatility in application.
- Sturdy and reliable design: Crafted with careful component selection to guarantee performance under the most demanding testing regimes.
Applications:
- Single and three-phase power line systems.
- Compliance with IEC 61000-4-5 for surge immunity testing.
- IEC 61000-4-12 power line testing compliance.
- ANSI C62.45 testing standards for power lines.
- Applicable across many IEC and EN product standards.
Specifications:
- Maximum Impulse Voltage: 8kV
- Maximum AC Voltage: 690VRMS (Phase-to-Phase)
- Residual voltage at test supply input: Maximum 15% of the applied impulse voltage
- EUT Connections: 4mm HV safety sockets
- Phase synchronization: Follows coupling path
- Coupling elements and paths managed by PSURGE 8000
- Power Supply: 85 – 264V, 50/60Hz