The Keithley 2304 Power Supply is expertly designed for voltage control and power consumption monitoring in the automated testing of portable, battery-operated devices. This versatile power supply is particularly optimized for wireless communication devices, such as cellular phones, which experience rapid load changes over brief time intervals. With exceptional voltage stability during pulse load alterations, the Keithley 2304 also has the capability to simultaneously monitor load currents, even during short pulses. Notably, this power supply can sink current, simulating the behavior of a discharged, rechargeable battery, making it ideal for testing chargers and charger-control circuits.
Key Features and Specifications
DC Voltage Output
- Output Voltage:
- 0 to +20VDC (Normal Output Response)
- 0 to +15VDC (Enhanced Output Response)
- Output Accuracy: ±(0.05% + 10mV)
- Programming Resolution: 5mV
- Readback Accuracy: ±(0.05% + 10mV)
- Output Voltage Settling Time: 5ms to within specified accuracy
- Load Regulation: 0.01% + 2mV
- Transient Response to 1000% Load Change:
- Normal Mode:
- Transient Recovery Time:
- <50µs to within 100mV of previous level
- <100µs to within 20mV of previous level
- Enhanced Mode:
- Transient Recovery Time:
- <40µs to within 100mV of previous level
- <80µs to within 20mV of previous level
- Transient Voltage Drop:
- Remote Sense: Automatic, with a 2V max drop in each lead. For every 1V change in the negative output lead due to load current change, add 2mV to the voltage load regulation specification.
DC Current
- Output Current: 5A max (not intended for parallel operation)
- Compliance Accuracy: ±(0.16% + 5mA)
- Programmed Compliance Resolution: 1.25mA
- Readback Accuracy:
- Readback Resolution:
- Current Sink Capacity:
- 3A max (Normal Output Response)
- 1A (Enhanced Output Response)
- Load Regulation: 0.01% + 1mA
Digital Voltmeter Input
- Input Voltage Range: 0 to +20VDC
- Input Impedance: 10Ω typical
- Maximum Voltage (either input terminal) With Respect to Output Low: –3V, +22V
- Reading Accuracy: ±(0.05% + 10mV)
DC General
- Measurement Time Choices: 0.01 to 10 PLC, in 0.01 PLC steps
- Average Readings: 1 to 10
- Reading Time 1: 31ms, typical
Pulse Current Measurement Operation
- Trigger Level: 5mA to 5A, in 5mA steps
- Trigger Delay: 0 to 100ms, in 10µs steps
- Internal Trigger Delay: 25µs
- High/Low Average Mode:
- Measurement Aperture Settings: 33.3µs to 833ms, in 33.3µs steps
- Average Readings: 1 to 100
- Burst Mode:
- Measurement Aperture: 33.3µs
- Conversion Rate: 3600/second, typical
- Number of Samples: 1 to 5000
- Transfer Samples Across IEEE Bus in Binary Mode: 4800 bytes/second, typical
- Long Integration Mode:
- Measurement time: 850ms (840ms) to 60 seconds in 16.7ms (20ms) steps
General
- Isolation (Low-Earth): 22VDC max
- Programming: IEEE-488.2 (SCPI)
- User-Definable Power-Up States: 5
- Rear Panel Connector: 8-position quick disconnect terminal block for output(4), sense (2), and DVM (2)
- Relay Control Jack: 2-channel, sink 150mA max, 15V max (accepts 0.173 in. Bantam-type plug (CS-1003-1))
- Power Consumption: 200VA max
- Input Power: 100V–240V AC, 50 or 60Hz (auto detected at power-up)
Other models in this series:
- Keithley 2303 High Speed Precision Power Supply
- Keithley 2304A High Speed Precision Power Supply