Keysight / Agilent MSOX3054A Oscilloscope, 500 MHz, 4 + 16 Ch., 4 GSa/s

Do you have a Keysight / Agilent MSOX3054A Oscilloscope, 500 MHz, 4 + 16 Ch., 4 GSa/s you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Keysight / Agilent

Category: Mixed Signal

Image Coming Soon

Keysight / Agilent MSOX3054A Oscilloscope

The Keysight MSOX3054A is an advanced four-channel oscilloscope from the renowned InfiniiVision 3000 X-Series, designed for unparalleled performance and versatility. This innovative device integrates five essential instruments into one, maximizing your budget without compromising on features.

Key Features

    • One million waveforms per second update rate for enhanced measurement accuracy.
    • MegaZoom IV smart memory technology for faster data processing.
    • Large 8.5-inch WVGA display ensuring clear visibility of waveforms.
    • Optional segmented memory for optimized data storage.
    • Industry's first 5-in-1 functionality, which includes:
      • High-performance Oscilloscope
      • Digital Logic Analyzer with 16 channels
      • Built-in 20 MHz function/arbitrary waveform generator with modulation capabilities
      • Integrated digital voltmeter for accurate voltage readings
      • Protocol analyzer to simplify communication analysis
    • Investment protection with fully upgradeable bandwidth capabilities up to 1 GHz.
    • Leading applications solutions for various measurement tasks.

Specifications

    • Bandwidth: -3 dB: 500 MHz
    • Calculated rise time: ≤ 700 ps (10 - 90%)
    • Input Channels:
      • 4 Analog Channels
      • 16 Digital Channels
    • Maximum Sample Rate:
      • 4 GSa/s (half channel)
      • 2 GSa/s (all channel)
    • Maximum Memory Depth:
      • Standard: 2 Mpts
      • Optional: 4 Mpts with segmented memory
    • Waveform Update Rate: > 1 million waveforms per second
    • Display: 8.5" WVGA, high-resolution clarity
    • Input Sensitivity Range: 1 mV/div to 5 V/div (1 MΩ and 50 Ω)
    • Vertical Resolution: 8 bits (12 bits measurement resolution with averaging)
    • Maximum Input Voltage: 300 Vrms, 400 Vpk, transient overvoltage 1.6 kVpk
    • Channel-to-Channel Isolation: > 100:1 across specified bandwidth

Trigger System

    • Trigger Sources: Analog channels (1-4), digital channels (D0-D15), line, external, WaveGen
  • Trigger Modes:
      • Normal (triggered)
      • Auto Mode
      • Single Trigger
      • Force Trigger
    • Trigger Sensitivity: Internal < 10 mV/div, External 200 mVpp (DC to 100 MHz)
    • Trigger Level Range: ±6 div from center screen, External ±8 V

Horizontal System

    • Time Base Range: 1 ns/div to 50 s/div
    • Time Base Accuracy: 25 ppm ± 5 ppm/year (aging)
    • Time Base Delay Time Range: Pre-trigger > 1 screen width or 250 µs, Post-trigger 1 s to 500 s

Vertical System

    • Vertical System Analog Channels: AC/DC coupled, selectable input impedance (1 MΩ ± 1%, 50 Ω ± 1.5%)
    • Maximum Input Dynamic Range: ±10 V about threshold

Acquisition System

    • Analog Channels Sample Rate: 4 GSa/s (half channel interleaved), 2 GSa/s (all channel)
    • Analog Channels Record Length: Up to 4 Mpts with optional upgrades

How can we help you with today?