Keysight N5182B (Agilent) MXG RF Vector Signal Generator
The Keysight N5182B MXG RF Vector Signal Generator is engineered to meet the exacting demands of R&D with superior precision and reliability. Elevate your testing capabilities with unparalleled performance in phase noise, ACPR, and channel coding.
Key capabilities include:
- Testing radar receiver sensitivity and characterizing ADC or mixer signal-to-noise ratio with unmatched phase noise and spurious performance.
- Driving power amplifiers and assessing nonlinear behavior with industry-leading ACPR and output power.
- Measuring wideband receivers and components, suitable for applications like 802.11ac WLAN, through a comprehensive 160 MHz RF bandwidth solution.
Key Features and Specifications of the Keysight N5182B MXG RF Analog Signal Generator:
- Signal Characteristics:
- Frequency Range: 9 kHz to 3 or 6 GHz
- +24 dBm specified power to 3 GHz with electronic attenuator
- -146 dBc phase noise at 1 GHz and 20 kHz offset
- ≤-73 dBc ACP W-CDMA 64 DPCH; < 0.4% EVM 160 MHz 802.11ac
- Modulation and Sweep:
- AM, FM, ØM, pulse, and narrow pulse modulation
- 10 MHz multifunction generator and LF output
- Digital step and list sweep modes
- I/Q Modulation: ASK, FSK, MSK, PSK, QAM, custom I/Q
- Baseband Generation and Signal Creation:
- 160 MHz internal baseband generator (+/- 0.2 dB flatness): arbitrary waveform and real-time I/Q
- 1 Gsample playback memory with 30 GB internal or 8 GB external, removable memory
- Arbitrary and real-time signals: LTE, HSPA+, WLAN, GNSS, DVB, and more
- Automation and Communication Interface:
- 1000BaseT LAN, LXI, USB 2.0, and GPIB compatibility
- SCPI, IVI-COM, and MATLAB drivers supported
- Backward compatibility with ESG, MXG, PSG, and 8648x
- Agilent USB power sensor compatible with embedded display and SCPI control
- Frequency Specifications:
- Frequency Range:
- Option 503: 9 kHz to 3 GHz
- Option 506: 9 kHz to 6 GHz
- Phase Offset: Adjustable in nominal 0.1 ° increments
- Frequency Switching Speed:
- CW Mode: SCPI Mode: ≤ 5 ms, typical
- List/Step Sweep Mode: ≤ 5 ms, typical
- Frequency Reference:
- Accuracy:
- Adjustment Resolution: < 1 x 10^-10, nominal
- Temperature Effects: < ± 2 x 10^-8 from 20 to 30 °C, nominal
- Line Voltage Effects: < ± 1 x 10^-9 for ± 10% change
- Reference Output:
- Amplitude: ≥ +4 dBm, nominal into 50 Ω load
- External Reference Input:
- Input Frequency, standard: 10 MHz
- Amplitude: 5 dBm ± 2 dB, nominal
- Sweep Modes:
- Operating Modes:
- Step Sweep: Equally spaced frequency and amplitude or logarithmically spaced frequency steps
- List Sweep: Arbitrary list of frequency and amplitude step; Simultaneous waveform sweeping
- Sweep Range: Within instrument frequency range
- Dwell Time: 100 μs to 100 s
- Number of Points:
- Step Change: Linear or logarithmic
- Triggering: Free run, trigger key, external, timer, bus (GPIB, LAN, USB)
- Amplitude Specifications:
- Output Parameters:
- Settable Range: +30 to –144 dBm
- Resolution: 0.01 dB, nominal
- Step Attenuator: 0 to 130 dB in 5 dB steps (electronic)
- Connector: Type N 50 Ω, nominal
- Maximum Output Power:
- > 10 MHz to 3 GHz: +18 dBm
- Maximum Reverse Power, Nominal:
- Amplitude Switching Speed:
- CW Mode: SCPI mode: ≤ 5 ms, typical
- List/Step Sweep Mode: ≤ 5 ms, typical
- Alternate Power Level Control:
- Switching time (via waveform markers): 20 μs within ± 1 dB, measured
- Functional power range: –15 dBm to –144 dBm, measured
- Spectral Purity Specifications:
- Harmonics:
- 9 kHz to 3 GHz: < –35 dBc
- > 3 to 4 GHz: < –35 dBc, typical
- > 4 to 6 GHz: < –53 dBc, typical
- Nonharmonics (CW Mode):
- 9 kHz to < 5 MHz: –65, nominal
- 750 MHz to < 1.5 GHz: –87
- Subharmonics (CW Mode):
- > 1.5 to 3 GHz: –82 dBc (–91)
- > 3 to 6 GHz: –74 dBc (–81)