Keysight / Agilent N7788B Optical Component Analyzer

Do you have a Keysight / Agilent N7788B Optical Component Analyzer you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Keysight / Agilent

Category: Optical Test Sets

Image Coming Soon

Keysight N7788B Optical Component Analyzer

The Keysight N7788B Component Analyzer stands at the forefront of optical technology, utilizing proprietary innovation to break new ground in precision measurement. This sophisticated instrument is designed to provide an exhaustive analysis of various optical parameters, positioning it as a pivotal tool for industry professionals involved in Polarization Mode Dispersion (PMD) and differential group delay (DGD) assessments.

Key Features

    • Comprehensive Measurement Capabilities: The N7788B assesses a complete set of parameters, including:
      • DGD/PMD
      • Polarization Dependent Loss (PDL)
      • Optical Power/Loss
      • TE/TM Loss
      • Second-order PMD
      • Principal States of Polarization (PSPs)
      • Jones and Mueller Matrices
    • High Throughput: Achieve a complete analysis across the C and L bands in under 10 seconds, enhancing efficiency in testing.
    • Remote Control Support: Enjoy seamless control through LAN or Internet connectivity, facilitating automation and troubleshooting.
    • Configurable Report Generation: Effortlessly generate customizable PDF reports, tailored to your specifications.
    • Real-Time Power Readout: Experience high throughput measurements with real-time power readout for non-connectorized components.
    • Barcode Scanner Integration: Simplifies the transfer of the DUT serial number for efficient data management.

Specifications

Wavelength Options:

    • 1270 nm to 1375 nm (Opt. 300, O-Band)
    • 1270 nm to 1375 nm, 1460 nm to 1620 nm (Opt. 400, O/C/L-Band)
    • 1460 nm to 1620 nm (Opt. 500, C/L-Band)
    • Operating wavelength range: 1260 nm to 1640 nm (SOP/DOP measurements outside specified range require manual calibration).

Differential Group Delay (DGD):

    • DGD Measurement Range: 0 ps to 1000 ps
    • DGD Uncertainty: 2.0 nm ± (30 fs + 3.0% * DGD)
    • PMD Measurement Range: 0 ps to 300 ps
    • PMD Repeatability: ± 3 fs

Loss Measurements:

  • PDL Measurement Uncertainty:
      • C-Band: ± (0.05 dB + 4% * PDL)
      • O-Band: ± (0.10 dB + 4% * PDL)
  • Insertion Loss Uncertainty:
      • C/L-Band: ± 0.03 dB
      • O-Band: ± 0.07 dB
    • Insertion Loss Dynamic Range: > 41 dB

Polarization Analysis:

    • SOP Uncertainty (Typical): 1.5°
    • DOP Uncertainty: ± 2.0%
    • Maximum Sampling Rate: 1 MHz

Optical Power Measurement:

    • Input Power Range: -50 dBm to +7 dBm
    • Maximum Safe Optical Input Power: +12 dBm

Polarization Control:

    • SOP Switching Time: < 10 μs
    • Maximum Safe Input Power: +20 dBm