Newport E100m Respiratory Ventilator

Do you have a Newport E100m Respiratory Ventilator you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Newport

Category: Respiratory Ventilators

Newport Newport E100m Respiratory Ventilator
Newport E100M Respiratory Ventilator: Versatility Meets Reliability in Patient Care
Introducing the Newport E100M Respiratory Ventilator, engineered to enhance patient care with its remarkable reliability and user-friendly design. This innovative device is ideal for various clinical settings, including emergency rooms, intra-hospital transport, and post-anesthesia recovery units, where space is at a premium and ease of use is paramount.
Equipped with advanced features like Advanced Trigger Control and Auto-Set Alarms, the Newport E100M simplifies ventilator management, allowing healthcare professionals to focus more on patient care. Its comprehensive alarm systems ensure continuous monitoring and swift responses to patient needs, enhancing overall safety.
Key Features of the Newport E100M Respiratory Ventilator:
  • Volume or Pressure Ventilation: Flexible ventilation modes to cater to diverse patient requirements.
  • Back-up Ventilation: Ensures consistent support even during unexpected scenarios.
  • DuoFlow PLUS: Optimized flow system that aids in patient comfort and reduces expiratory resistance, making spontaneous breathing easier.
  • 8-Hour Internal Battery Back-up: Reliable power source for intra-hospital transport and emergencies.
  • Built-in Air/Oxygen Mixer: Efficient mixing capabilities provide precise respiratory support.

The compact and efficient design of the Newport E100M allows for easy mobility and setup in space-restricted environments, making it a dependable choice for both subacute and long-term care applications. Its versatility eliminates the need for age-specific or application-limited equipment, offering significant cost savings for healthcare facilities.
Enhanced Safety Features:
With functionalities such as Apnea Back-up Ventilation and a Remote Alarm Outlet, the E100M is designed with maximum patient safety in mind. The Auto-Set Alarm feature automatically adjusts high and low pressure alarm settings to ensure optimal performance.
Comprehensive Monitoring Capabilities:
Detailed monitoring options provide insights into pivotal parameters, including Peak, Mean, and Base Airway Pressure, as well as Set Tidal Volume, I:E ratio, Total Frequency, and Battery Charge percentage.
The Newport E100M Respiratory Ventilator stands as a reliable and flexible solution for modern healthcare needs, delivering exceptional performance and ease of use for clinicians while prioritizing patient comfort and safety. Elevate your respiratory care capabilities with this outstanding ventilator.

Newport E100m Respiratory Ventilator Specifications


Physical Weight & Dimensions

  • Height: 10.5 inches (26.7 cm)
  • Width: 9.5 inches (24.1 cm)
  • Depth: 6.5 inches (16.5 cm)
  • Weight: 18 lbs (8.2 kg)

Modes & Settings

  • Pressure or Volume:
  • A/CMV
  • SMIV
  • SPONT + APNEA A/CMV
  • SPONT
  • FlO2: 0.21 - 1.0
  • V(Mandatory Flow): 1 - 100 L/min
  • V(Inspiratory Flow): 0.1 - 3.0 sec
  • VTTidal Volume: 5 - 5000 ml
  • ƒ (Frequency Rate): 1 - 120 breaths/min
  • PEEP/CPAP: 0 - ? 25 cmH2O
  • P Limit (Pressure Limit): 0 - 120 cmH2O
  • P Trig (sensitivity): -10 - ? 25 cmH2O
  • Automatic Trigger Control: On/Off
  • Time Limited Demand Flow: 0 - 1.0 sec
  • Paw Alarm (Low): 3 - 118 cmH2O
  • Paw Alarm (High): 5 - 120 cmH2O
  • Auto-Set Alarm: On/Off
  • Apnea: 0, 15, 30 seconds
  • NEB Gas Source: On/Off
  • PROX/PATIENT Outlet Monitoring Selection: On/Off
  • Manual Inflation: Operator Controlled, 4 sec Max.
  • SPONT V2: Adjustable 0 to 15+ L/min
  • SPONT V1: 0 L/min or 8 L/min
  • Pressure Gauge: -10 to +120 cmH2O

Monitored Parameters/Indicators

  • Tidal Volume: Paw Peak
  • I:E Ratio: Mean
  • ƒ total: Base
  • Battery in Use: tl ? tE (Max 4:1)
  • Battery Charge %: Spont Detect

Alarms

  • Audible and Visual:
  • Paw High
  • Paw Low
  • Battery Low
  • Low Baseline (Paw Low)
  • High Baseline (Paw High / Paw Low)
  • Audible Only:
  • Fault
  • Gas Supply Source Failure
  • Power Failure
  • Alarm Silence Reset: 60 Sec

Electrical

  • Power Requirements:
  • 100, 120 VAC 0.14A Max
  • 220, 240 VAC 0.07A Max
  • 50/60 Hz
  • Internal Battery:
  • 6-8 Hours typical
  • (Minimum 4 Hours @ Max Load)

How can we help you with today?