NH Research 9200-4912 Battery Tester, 120V, 200A, 8kW Source/12kW - 144kW Discharge

Do you have a NH Research 9200-4912 Battery Tester, 120V, 200A, 8kW Source/12kW - 144kW Discharge you want to sell?

We buy used equipment! Learn about selling

Manufactured by: NH Research

Category: Battery Test Systems

Image Coming Soon

RENT NH RESEARCH 9200-4912 BATTERY TESTER (Call for Availability)

The NH Research 9200-4912 is an advanced, expandable Battery Module/Pack Test System designed for thorough automated characterization, power cycling, and life-cycle testing of battery modules and packs. Featuring a highly flexible tester-per-channel design and built-in digital measurements, this system delivers exceptional performance with various control interface options, including a user-friendly Touch-Panel.

Features and Specifications of the NH Research 9200-4912 Battery Tester include:

Features of the NHR 9200-4912 include:

    • Unmatched configuration capability
    • Custom waveform/profile generation
    • Microsecond voltage, current, and mode transition times
    • Built-in digital measurements with charting and scope displays
    • Three test system control options, including a Touch-Panel interface
    • Expandable from 12 to 252 kW with bi-directional DC loads (40, 120, or 600 V)
    • 87% efficiency returning discharge power to AC mains
    • Multiple safety layers designed to protect batteries during testing
    • Battery emulation and burn-in applications supported

Specifications of the NHR 9200-4912 include:

    • Program Capability:
      • Operating states:
        • Charge (source)
        • Discharge (load)
        • Standby
        • Battery
      • Charge/Discharge modes:
        • Constant-voltage (CV)
        • Constant current (CC)
        • Constant power (CP)
        • Constant resistance (CR)
      • Charging envelope: 0 - 120V, 8kW, 200A
      • Discharging envelope: 4 - 120V, 12kW, 200A
        • Slew rate: 0.033V/S - 120 kV/S, 0.055A - 200kA/S
        • Current charge time: < 5mS
        • Current reverse time: < 10mS
      • Parallelability: Synchronous control for up to 12 channels (144kW)
    • Macro Test Profiles:
      • Development source: Touch-Panel, Import from Excel or User's System Controller
      • Maximum steps: 1000
      • Minimum time delay: 5μS
      • Maximum step delay: 1 mS - 7 days
    • Programming:
      • Voltage:
        • Range: 0-120V
        • Accuracy: 0.1% + 0.1%
        • Resolution: 0.005%
      • Current:
        • Range: ± 200A
        • Accuracy: 0.2% + 0.2%
        • Resolution: 0.005%
      • Power:
        • Range: ± 12KW
        • Accuracy: 0.4% + 0.4%
        • Resolution: 0.005%
      • Resistance:
        • Range: 0 - 100Ω
        • Accuracy: 2%
        • Resolution: 0.005%
      • Slew rate:
        • Voltage: 0.034V/s - 240V/ms
        • Current: 0.55A/s - 1000A/ms
        • Resistance: 0.028Ω/s - 100Ω/ms
        • Power: 0.002W/s - 8kW/ms
    • Test measurement (4-Wire):
      • Voltage, DC average:
        • Range: 0 - 120V
        • Accuracy: 0.05% + 0.05%
        • Resolution: 0.005%
      • Current, DC average, Amp-Hr:
        • Range: 0 - 200A
        • Accuracy: 0.1% + 0.1%
        • Resolution: 0.005%
      • Power, Ah, kWh:
        • Range: ± 12KW
        • Accuracy: 0.4% + 0.4%
        • Resolution: 0.005%
      • Time:
        • Range: 1ms - 1Yr
        • Accuracy: 0.1%
        • Resolution: 0.005%
      • Control:
        • Local user interface: Touch-Panel with graphic meters and controls plus Macro development/execution screens
        • Ext. system communication: LAN (Ethernet)
        • Drivers: LabVIEW, IVI-COM, IVI-C
        • Analog current monitor: 0 to +10V charge/0 to -10V discharge
        • Analog voltage monitor: 0 to +10V full scale voltage
      • Safety:
        • Isolation AC input: 1000V AC to DC output / 1000V AC input to chassis
        • Isolation UUT input: 1000 V UUT to chassis
        • Programmable safety limits: Over-Voltage (OV), Under-Voltage (UV), Over-Current (OC), Over-Power (OP)
        • Internal protection: Over/Under-Voltage, Over-Current, Over-Power, Internal Over-Temperature
        • Interlocks: External user input, emergency stop, and rear service door
        • Watchdog timer: Continuously monitors control communications