Orion™ Two-Electrode Conductivity Cells

Do you have a Orion™ Two-Electrode Conductivity Cells you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Thermo Orion

Category: Instruments

Thermo Orion Orion™ Two-Electrode Conductivity Cells

Orion™ Two-Electrode Conductivity Cells

Enhance your analytical capabilities both in the laboratory and in the field with the versatile Orion™ Two-Electrode Conductivity Cells. Engineered for precision and reliability, these cells come in various materials and measurement ranges, making them suitable for a multitude of applications.

Available Models and Specifications:

Model 011010A & 011010

    • Material: Glass/Platinum
    • Nominal Cell Constant: 1.0 cm-1
    • Measurement Range: 1 µS/cm to 200 mS/cm
    • Application: Laboratory use

Model 011020A, 011020 & 9902BN

    • Material: Glass/Platinum
    • Nominal Cell Constant: 0.1 cm-1
    • Measurement Range: 0.1 µS/cm to 100 µS/cm
    • Application: Laboratory use and ultra-pure water

Model 011050MD, 011050A & 011050

    • Material: Epoxy/Platinum
    • Nominal Cell Constant: 1.0 cm-1
    • Measurement Range: 1 µS/cm to 20 mS/cm
    • Application: Field or laboratory use

Model 011510MD & 011510

    • Material: Epoxy/Graphite
    • Nominal Cell Constant: 1.0 cm-1
    • Measurement Range: 10 µS/cm to 200 mS/cm
    • Application: Field or laboratory use

Model 013016MD, 013016A & 013016D

    • Material: Steel (V4A)
    • Nominal Cell Constant: 0.1 cm-1
    • Measurement Range: 0.01 µS/cm to 300 µS/cm
    • Application: Laboratory use and ultra-pure water

Model 018020MD

    • Material: Glass/Platinum
    • Nominal Cell Constant: 10 cm-1
    • Measurement Range: 10 µS/cm to 2000 mS/cm
    • Application: High electrolyte concentration solutions

Recommended For:

The Orion™ Two-Electrode Conductivity Cells are designed for both laboratory and field applications, providing the accuracy and reliability necessary for diverse testing environments.

Quick Specs Overview:

Cat. No. Cable Length Meter Compatibility Measurement Range Application Approximate Cell Constant Cell Material Dimensions Min/Max Immersion
011050MD A 1.5 m Star Series 1 µS/cm to 20 mS/cm Lab and Field 1.0 cm-1 Epoxy/Platinum Dia - 12 mm, Length - 120 mm 20/90 mm
011050 B 1 m 150A plus, 145A plus, 125A plus, 115A plus, 05A plus 1 µS/cm to 20 mS/cm Lab and Field 1.0 cm-1 Epoxy/Platinum Dia - 12 mm, Length - 120 mm 20/90 mm
011020 B 1 m 150A plus, 145A plus, 125A plus, 115A plus, 05A plus 0.1 µS/cm to 100 µS/cm Boiler feedwater, ultra-pure water 0.1 cm-1 Glass/Platinum Tip dia - 17 mm, Tip length - 22 mm, Dia - 13 mm, Length - 120 mm 25/120 mm
011020A F 1 m 555A, 550A, 162A, 136S, 135A, 131S, 130A 0.1 µS/cm to 100 µS/cm Boiler feedwater, ultra-pure water 0.1 cm-1 Glass/Platinum Tip dia - 17 mm, Tip length - 22 mm, Dia - 13 mm, Length - 120 mm 25/120 mm
011010 B 1 m 150A plus, 145A plus, 125A plus, 115A plus, 05A plus 1 µS/cm to 200 mS/cm Lab 0.1 cm-1 Glass/Platinum Dia - 13 mm, Length - 120 mm 25/120 mm
011010A F 1 m 555A, 550A, 162A, 136S, 135A, 131S, 130A 1 µS/cm to 200 mS/cm Lab 0.1 cm-1 Glass/Platinum Dia - 13 mm, Length - 120 mm 25/120 mm