Discover the Philips IntelliVue M3001A MMS Module Front Connector Bezel, designed to enhance your patient monitoring capabilities. This essential component features SpO2, ECG, NiBP, IBP, and temperature monitoring capabilities, ensuring comprehensive data at your fingertips. Crafted for durability and optimal performance, the bezel is new and ready for patient use, making it an ideal addition to your medical equipment inventory. Upgrade your monitoring system with this vital accessory that supports critical care and enhances patient safety. Experience reliability and precision with the Philips IntelliVue M3001A today!
Philips IntelliVue M3001A MMS Module Specifications:

  • Model: M3001A
  • Connector Type: Front Connector Bezel
  • SpO2 Measurement:
  • Technology: Reflectance and Transmittance
  • Accuracy: ±2% (SpO2 70-100%)
  • Range: 0% - 100% SpO2

  • ECG Measurement:
  • Lead Types: 3-lead, 5-lead (configurable)
  • Frequency Response: 0.05 - 100 Hz
  • Measurement Range: -10 mV to +10 mV

  • Non-Invasive Blood Pressure (NiBP):
  • Measurement Method: Oscillometric
  • Pressure Range: 0 - 300 mmHg (0 - 40 kPa)
  • Accuracy: ±5 mmHg (±0.67 kPa)

  • Invasive Blood Pressure (IBP):
  • Pressure Range: -300 to +300 mmHg (-40 to +40 kPa)
  • Accuracy: ±1 mmHg (±0.13 kPa)

  • Temperature Measurement:
  • Sensor Type: Thermistor, Temperature Probes
  • Measurement Range: 25°C - 45°C (77°F - 113°F)
  • Accuracy: ±0.1°C (±0.18°F)

  • Power Supply:
  • Input Voltage: 100 - 240 VAC
  • Frequency: 50/60 Hz
  • Power Consumption: 30 W

  • Dimensions:
  • Width: 8.27 in (210 mm)
  • Height: 1.97 in (50 mm)
  • Depth: 6.69 in (170 mm)

  • Weight:
  • Approximately 2.65 lbs (1.2 kg)

  • Communication Interface:
  • Protocols: HL7, DICOM (optional)
  • Connectivity: Wired and Wireless options available

  • Operating Conditions:
  • Temperature: 0°C - 40°C (32°F - 104°F)
  • Humidity: 10% - 95% (non-condensing)
  • Atmospheric Pressure: 700 - 1060 hPa

  • Storage Conditions:
  • Temperature: -40°C to 70°C (-40°F to 158°F)
  • Humidity: 5% - 95% (non-condensing)

  • Regulatory Compliance:
  • CE Marked
  • FDA Cleared