Philips IntelliVue M3001A MMS Module Front Connector Bezel SpO2 ECG NiBP Text

Do you have a Philips IntelliVue M3001A MMS Module Front Connector Bezel SpO2 ECG NiBP Text you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Philips

Category: Module Parts

Philips Philips IntelliVue M3001A MMS Module Front Connector Bezel SpO2 ECG NiBP Text
Product Description: Philips IntelliVue M3001A MMS Module Front Connector Bezel
Enhance the functionality of your Philips IntelliVue M3001A MMS module with the reliable front connector bezel. This essential component, designed with precision, features clear English text and is engineered to withstand the demands of a rigorous clinical environment, ensuring optimal performance in medical settings.
Compatibility:
The Philips IntelliVue M3001A MMS module front connector bezel is compatible with modules featuring option strings A01 for FAST SpO2, A03 for Masimo SET SpO2, C00 for 5 lead ECG, and C12 for 12 lead ECG. This versatility makes it a crucial addition to your medical equipment toolkit.
OEM Part Number:
451261024391
This brand new front connector bezel is ready for professional installation, making it an ideal choice for healthcare facilities looking to maintain the high standards of their Philips IntelliVue equipment. Invest in quality and reliability with this essential medical component.
Philips IntelliVue M3001A MMS Module Specifications

  • Model: M3001A
  • Type: MMS Patient Monitor Module
  • Parameters Monitored:
  • SpO2 (Pulse Oximetry)
  • ECG (Electrocardiogram)
  • NiBP (Non-invasive Blood Pressure)

Physical Specifications:
  • Dimensions:
  • Width: 5.51 inches (140 mm)
  • Height: 1.57 inches (40 mm)
  • Depth: 6.02 inches (153 mm)
  • Weight:
  • Approx. 1.5 lbs (0.68 kg)

SpO2 Specifications:
  • Measurement Range: 0% to 100%
  • Accuracy: ±2% for 70% to 100%, ±3% for 0% to 69%

ECG Specifications:
  • Lead Types: 3-lead, 5-lead
  • Frequency Response: 0.05 to 150 Hz
  • Gain Accuracy: ±5%

NiBP Specifications:
  • Measurement Range:
  • Systolic: 20 to 300 mmHg (2.7 to 40 kPa)
  • Diastolic: 10 to 200 mmHg (1.3 to 26.7 kPa)
  • Accuracy: ±5 mmHg (0.67 kPa)

Electrical Specifications:
  • Input Voltage: 100-240 V AC
  • Power Consumption: 40 W maximum

Interface:
  • Front Connector:
  • Patient cable ports for SpO2, ECG leads, and NiBP cuff

Operating Conditions:
  • Temperature: 32°F to 113°F (0°C to 45°C)
  • Humidity: 15% to 95% non-condensing
  • Altitude: Up to 15,000 ft (4,600 m)

Storage Conditions:
  • Temperature: -40°F to 158°F (-40°C to 70°C)
  • Humidity: 10% to 100% non-condensing

Compliance:
  • FDA: Approved
  • ISO standards: Compliance with relevant medical device standards

Note: Ensure to refer to the manufacturer’s manual for specific installation and operational guidelines.