Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 FAST SpO2 NiBP 5 Lead ECG IBP Temp

Do you have a Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 FAST SpO2 NiBP 5 Lead ECG IBP Temp you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Philips

Category: Miscellaneous

Image Coming Soon
Introducing the Philips IntelliVue M3001A MMS Module Parameter Boards A01C06, designed to deliver exceptional monitoring capabilities in clinical settings. This advanced device features fast SpO2 measurements, Non-Invasive Blood Pressure (NiBP) monitoring, a 5 Lead ECG, Invasive Blood Pressure (IBP), and temperature measurement, making it an essential tool for healthcare professionals.
Engineered for reliability, the IntelliVue M3001A supports seamless integration into your existing monitoring systems, enhancing the efficiency of patient care. Its intuitive interface and robust design ensure that critical parameters are continuously and accurately monitored, providing peace of mind to medical teams.
Whether you're upgrading your medical equipment or enhancing your monitoring capabilities, the Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 is a vital addition to any healthcare facility. Experience the benefits of high-quality, real-time monitoring with this state-of-the-art module.
Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 FAST Specifications:

  • SpO2:
  • Measurement Range: 0% - 100%
  • Accuracy: ±2% (70% - 100%), ±3% (40% - 69%)

  • NiBP (Non-invasive Blood Pressure):
  • Measurement Range:
  • Systolic: 40 - 260 mmHg (5.3 - 34.7 kPa)
  • Diastolic: 10 - 215 mmHg (1.3 - 28.7 kPa)
  • Mean: 20 - 230 mmHg (2.7 - 30.7 kPa)
  • Accuracy: ±5 mmHg or 5% (whichever is greater)

  • ECG (5 Lead):
  • Lead Types: I, II, III, aVR, aVL, aVF, V1-V6
  • Frequency Response: 0.05 - 150 Hz
  • Calibration: ±1 mV

  • IBP (Invasive Blood Pressure):
  • Measurement Range: -50 to 300 mmHg (-6.7 to 40 kPa)
  • Accuracy: ±1 mmHg (at 0-300 mmHg)

  • Temperature:
  • Measurement Range:
  • Adult: 30°C to 44°C (86°F to 111.2°F)
  • Pediatric: 32°C to 42°C (89.6°F to 107.6°F)
  • Neonate: 36°C to 38°C (96.8°F to 100.4°F)
  • Accuracy: ±0.1°C (±0.2°F)

Additional Information:
  • Power Supply: Compatible with Philips IntelliVue patient monitors.
  • Connectivity: Integrates with hospital networks for data transmission.
  • Dimensions: Specific dimensions may vary based on configuration.
  • Weight: Typically lightweight for easy handling.

This device is designed for monitoring multiple vital signs and is commonly used in acute care settings. Make sure to verify all specifications with the manufacturer for compliance with local regulatory standards.