Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 FAST SpO2 NiBP 5 Lead ECG IBP Temp

Do you have a Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 FAST SpO2 NiBP 5 Lead ECG IBP Temp you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Philips

Category: Module Parts

Philips Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 FAST SpO2 NiBP 5 Lead ECG IBP Temp
Introducing the Philips IntelliVue M3001A MMS Module Parameter Boards A01C06, designed to enhance your monitoring capabilities. These state-of-the-art parameter boards are engineered for seamless integration with Philips IntelliVue M3001A MMS Modules, making them an essential component for efficient patient monitoring. Featuring FAST SpO2, NiBP, 5 Lead ECG, IBP, and temperature capabilities, these boards provide comprehensive data to help healthcare professionals deliver the best care.
Thoroughly tested and meticulously cleaned, these parameter boards meet rigorous manufacturer specifications, ensuring reliable performance in any clinical environment. Designed for compatibility with Philips IntelliVue M3001A MMS modules featuring hardware revision C, these boards are ready for immediate installation.
OEM Part Number:
  • Elevate your medical equipment setup with Philips IntelliVue M3001A Parameter Boards and experience precision monitoring like never before.
Philips IntelliVue M3001A MMS Module Parameter Boards A01C06 Specifications

  • SpO2:
  • Measurement Range: 0% to 100%
  • Accuracy: ±2% (70% to 100%); ±3% (50% to 69%); unspecified (<50%)

  • NiBP (Non-invasive Blood Pressure):
  • Measurement Range: Systolic 20 to 300 mmHg (2.67 to 40.00 kPa), Diastolic 10 to 200 mmHg (1.33 to 26.67 kPa)
  • Accuracy: ±5 mmHg (±0.67 kPa)

  • ECG (Electrocardiogram):
  • Lead Configuration: 5 Lead
  • Frequency Response: 0.05 to 150 Hz
  • Accuracy: ±5% or ±0.5 mV

  • IBP (Invasive Blood Pressure):
  • Measurement Range: -50 to 300 mmHg (-6.67 to 40.00 kPa)
  • Accuracy: ±2 mmHg (±0.27 kPa)

  • Temperature:
  • Measurement Range: 25°C to 45°C (77°F to 113°F)
  • Accuracy: ±0.1°C (±0.2°F)

  • Power Supply:
  • Operating Voltage: 100 to 240 VAC (50/60 Hz)

  • Connections:
  • Protocols: Digital and Analog I/O
  • Communication: RS-232, Ethernet (if applicable)

  • Dimensions:
  • Size: 8.27 in x 6.50 in x 3.93 in (210 mm x 165 mm x 100 mm)

  • Weight:
  • Approx: 3.5 lb (1.6 kg)

  • Environmental Conditions:
  • Operating Temperature: 0°C to 40°C (32°F to 104°F)
  • Storage Temperature: -20°C to 60°C (-4°F to 140°F)

  • Certifications:
  • CE Mark, FDA approved

Note: Specifications may vary depending on the specific configuration and options available with the device. Always refer to the manufacturer's technical documentation for detailed information.