Respironics Novametrix Tidal Wave 710Sp Monitor

Do you have a Respironics Novametrix Tidal Wave 710Sp Monitor you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Respironics

Category: Monitors - Refurbished

Respironics Respironics Novametrix Tidal Wave 710Sp Monitor
Product Description for Respironics Novametrix Tidal Wave 710Sp Monitor
Discover unparalleled monitoring capabilities with the Respironics Novametrix Tidal Wave 710Sp Monitor, a state-of-the-art portable handheld pulse oximeter and CO2 monitor equipped with advanced SpO2 functionality. As a leader in portable monitoring technology, this device stands out as the only handheld, mainstream capnograph currently available, making it an essential tool for healthcare professionals who require immediate and accurate feedback on a patient’s airway condition and ventilatory status.

Key Features:


  • Integrated Pulse Oximeter: Experience comprehensive monitoring with the built-in pulse oximeter, allowing for simultaneous tracking of blood oxygen levels alongside CO2 measurements.
  • Handheld Convenience: Designed for portability, the Tidal Wave 710Sp is lightweight and easy to use in various clinical settings, from emergency rooms to outpatient facilities.
  • Real-time Feedback: The device provides instant monitoring of capnography, ensuring clinicians have the critical data needed for effective patient management.
  • 30-Minute Trend Display: Keep track of patient data trends effortlessly with the 30-minute on-screen graphic trend feature, giving you valuable insights into respiratory changes over time.
  • Alert System: Equipped with visual and audible "no respiration" alerts, the Tidal Wave 710Sp ensures that healthcare providers are promptly notified of any critical changes in respiratory status.

Battery and Maintenance:


  • User-Friendly Battery Replacement: This monitor incorporates user-replaceable disposable and rechargeable battery packs, which provide up to 5.5 hours of operation. This innovative design eliminates downtime waiting for batteries to charge.
  • No Calibration Required: Benefit from hassle-free operation as the Tidal Wave 710Sp does not require calibration for CO2, allowing for seamless use in time-sensitive situations.

Available Configurations:


The Tidal Wave product line offers additional configurations to meet varied clinical needs:
  • Tidal Wave Model 610: Handheld Mainstream Capnograph
  • Tidal Wave Model 615: Handheld Capnograph with Mainstream and Sidestream Sampling
  • Tidal Wave Sp Model 715: Handheld Mainstream Capnograph/Pulse Oximeter with Sidestream Sampling Capabilities

Elevate your patient monitoring with the Respironics Novametrix Tidal Wave 710Sp Monitor, where technology meets innovative design for superior respiratory care.

Respironics Novametrix Tidal Wave 710Sp Monitor Specifications


Capnograph


  • Principle of Operation: Solid state mainstream sensor. Single beam, non-dispersive infrared (NDIR) absorption, ratiometric measurement.
  • Initialization Time: Capnogram within 15 seconds, full specifications within 60 seconds.
  • Calibration: No calibration required.

#

Capnostat® Mainstream CO2 Sensor

  • Size: 1.30 × 1.67 × 0.85 inches (3.30 × 4.24 × 2.16 cm)
  • Weight: 0.64 oz (18 grams), cable excluded
  • Shock Resistance: Withstands repeated six foot (1.83 m) drops to a hard surface.

#

CO2 (Carbon Dioxide)

  • Range: 0 - 150 mmHg (0 - 20 kPa)
  • Accuracy:
  • ±2 mmHg (for 0 - 40 mmHg)
  • ±5% of reading (for 41 - 70 mmHg)
  • ±8% of reading (for 71 - 150 mmHg)
  • Resolution: 1 mmHg
  • Response Time: 60 ms
  • Units: mmHg, kPa, or %
  • Compensations: N2O & O2 (selectable), Pb (automatic)
  • Capnogram: Selectable sweep speed

#

Respiratory Rate

  • Accuracy: ±1 br/min
  • Range: 0 - 150 br/min
  • Resolution: 1 br/min

#

Sampling Flow Rate (Model 715 only)

  • Flow Rate: 180 ml/min for non-intubated patients
  • Response Time: Less than 200 ms at 180 ml/min flow

Pulse Oximeter


  • Principle of Operation: Red/Infrared absorption.

#

SpO2 (Oxygen Saturation)

  • Range: 0-100%
  • Accuracy:
  • ±2% SpO2 (for 80-100% SpO2)
  • Unspecified for 0-79% SpO2
  • Resolution: 1%
  • Averaging: Menu selectable 2 or 8 seconds

#

Pulse Rate

  • Range: 30 - 250 bpm
  • Accuracy: ±1% of full scale
  • Resolution: 1 bpm
  • Averaging: 8 seconds

#

Sensors

  • Reusable Y-Sensor (can be sterilized and used with all patient populations); reusable adult finger sensor.

#

Plethysmogram

  • Pulsatile waveform.

General


#

Alerts

  • Limits: Adjustable limits for ETCO2, SpO2, Respiratory Rate, and Pulse Rate. No Respiration Detected adjustable timeout.
  • Audio: Adjustable volume, two minute silence or off (LED indicators).
  • Visual: On-screen and LED.

#

Display

  • Type: Dot matrix, backlit (LCD).
  • Size: 2.2 × 1.1 inches.

#

Trending Capabilities

  • Memory: 24 hours, battery backed.
  • Format: 30 minute on-screen or printed in trend or tabular mode. Download data to personal computer for use with NovaCARD™ software.

#

Communication Output

  • RS232 to Seiko DPU-414 printer, NovaCARD software, or computer.

#

Physical

  • Size (H × W × D): 8 × 3.75 × 1.875 inches (20 × 9.5 × 4.8 cm).
  • Weight: 793 grams (28 oz.).

#

Electrical

  • External Supply (optional):
  • Input: 120 VAC 60 Hz, or 220 VAC 50 Hz.
  • Battery:
  • Nickel-Metal-Hydride (NiMH): 4.5 hour life.
  • Standard AA lithium: 5.5 hour life.

#

Environmental

  • Operating Temperature: 0 to +40°C (32 - 104°F).
  • Operating Humidity: 0 to 90% RH non-condensing.