Rohde & Schwarz ESR26 EMI Test Receiver, 9 kHz to 26.5 GHz

Do you have a Rohde & Schwarz ESR26 EMI Test Receiver, 9 kHz to 26.5 GHz you want to sell?

We buy used equipment! Learn about selling

Image Coming Soon

RENT R&S ESR26 (call for availability)

The R&S ESR26 EMI Test Receiver is a versatile dual instrument designed to measure electromagnetic disturbances while also serving as a comprehensive signal and spectrum analyzer for laboratory applications. This sophisticated device employs an FFT-based time domain scan for rapid measurements and offers real-time spectrum analysis, providing a detailed insight into disturbance signals with a myriad of diagnostic tools. The R&S ESR26 stands out for its user-friendly design, featuring a straightforward display and an intuitive touchscreen interface, making complex operations seamless.

Key Features and Specifications of the R&S ESR26 EMI Test Receiver include:

  • Features
      • EMI test receiver and signal/spectrum analyzer combined in a single unit
      • Meets compliance with CISPR 16-1-1 Ed. 3.1 standards
      • Integrated 20 dB preamplifier for preselection
      • Ultra-fast time domain scan, complemented by a conventional stepped frequency scan
      • Realtime spectrum analysis with spans up to 40 MHz, facilitating detailed investigation of disturbance signals
      • Powerful measurement capabilities and analysis functions available in both frequency and time domains
      • High-resolution time domain display (50 μs)
      • Automatic test routines to streamline the measurement process
      • Convenient operation with a clear display
      • Robust and compact design, ideal for mobile applications
  • Specifications
    • Frequency
        • Frequency Range: 9 kHz to 26.5 GHz
    • Level
      • Max RF level (CW):
          • RF attenuation ≥ 10 dB; RF preamplifier off: 30 dBm (= 1 W)
          • RF attenuation ≥ 10 dB; RF preamplifier on: 23 dBm (= 0.2 W)
      • Max Pulse Voltage:
        • RF attenuation ≥ 10 dB:
            • Input 1: 150 V
            • Input 2: 450 V
      • Max Pulse Energy:
        • RF attenuation ≥ 10 dB; 10 μs
            • Input 1: 1 mWs
            • Input 2: 20 mWs
      • 1 dB Compression:
          • RF attenuation 0 dB; RF preamplifier and preselection off: +3 dBm, nominal
    • IF and Resolution Bandwidths
        • Analyzer Mode (span ≥ 10 Hz) and Receiver Mode: 10 Hz to 10 MHz (–3 dB) in 1/2/3/5/10 steps
        • Analyzer and Receiver Mode: 200 Hz, 9 kHz, 120 kHz (–6 dB), 1 MHz (impulse bandwidth)
        • Preselection: Can be switched off in analyzer mode: 16 Fixed Filters
        • Preamplifier: Can be switched on/off: 1 kHz to 26.5 GHz, 20 dB gain, nominal
    • Measurement Time
      • Analyzer Mode (Sweep Time):
          • span = 0 Hz: 1 μs to 16,000 s
          • span ≥ 10 Hz (swept): 1 ms to 16,000 s
          • span ≥ 10 Hz (FFT): 7 μs to 16,000 s
        • Receiver Mode (Stepped Frequency Scan): 50 μs to 100 s (per frequency)
        • Receiver Mode (Time Domain Scan): 50 μs to 100 s (per frequency subrange)
    • Frequency Step Size
        • Receiver Mode (Stepped Frequency Scan): min. 1 Hz
        • Receiver Mode (Time Domain Scan): 0.25 × IF bandwidth
    • Detectors
      • Receiver Mode:
          • maximum peak
          • minimum peak
          • quasi-peak
          • RMS
          • average
          • average with meter time constant (CISPR average)
          • RMS average (CISPR-RMS)
    • Displayed Average Noise Level (DANL)
      • Receiver Mode, Nominal, Average Detector (AV), RF Attenuation 0 dB, Termination 50 Ω:
        • Preamplifier Off:
            • 500 MHz, bandwidth 120 kHz: < 6 dBμV
            • 3 GHz, bandwidth 1 MHz: < 17 dBμV
        • Preamplifier On:
            • 500 MHz, bandwidth 120 kHz: < -7 dBμV
            • 3 GHz, bandwidth 1 MHz: < 5 dBμV
    • Number of Sweep (Trace) Points
        • Analyzer Mode (Standard): 101 to 32,001
        • Analyzer Mode (EMI): 101 to 200,001
        • Receiver Mode: Max 4,000,000
        • Realtime Analyzer (Option): 801
    • Total Measurement Uncertainty
      • CW signal, level 0 dB to –70 dB below reference level, S/N > 20 dB, auto sweep time, RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, preselection on, span/RBW < 100, 95% confidence level, +20°C to +30°C
          • 9 kHz ≤ f < 3.6 GHz: 0.46 dB
          • 3.6 GHz ≤ f ≤ 26.5 GHz: 0.57 dB