Rohde & Schwarz ESR3 EMI Test Receiver, 9 kHz to 3.6 GHz

Do you have a Rohde & Schwarz ESR3 EMI Test Receiver, 9 kHz to 3.6 GHz you want to sell?

We buy used equipment! Learn about selling

Image Coming Soon

RENT R&S ESR3 (call for availability)

The R&S ESR3 EMI Test Receiver is an advanced dual-function instrument designed for precision measurement of electromagnetic disturbances. In addition to its role as an EMI test receiver, it operates as a fully equipped signal and spectrum analyzer, making it perfect for comprehensive lab applications. The ESR3 features rapid measurement capabilities, employing an FFT-based time domain scan, and offers in-depth analysis and history of disturbance signals through real-time spectrum analysis, supported by an array of diagnostic tools. Its robust yet compact design, coupled with a user-friendly interface and intuitive touchscreen display, ensures ease of use and mobility in various testing environments.

Key Features and Specifications of the R&S ESR3 EMI Test Receiver:

  • Features
      • Integrates EMI test receiver and signal/spectrum analyzer into one unit
      • Meets CISPR 16-1-1 Ed. 3.1 compliance standards
      • Field-selectable preselection with an integrated 20 dB preamplifier
      • Ultra-fast time domain scan in conjunction with conventional stepped frequency scans
      • Real-time spectrum analysis offering a span of up to 40 MHz for thorough disturbance signal investigation
      • Advanced measurement and analysis capabilities available in both frequency and time domains
      • High-resolution time domain display (50 μs)
      • Automatic test routines for streamlined operation
      • Simplified user interface with clear display for enhanced operation
      • Compact and durable design, ideal for mobile applications
  • Specifications
    • Frequency
        • Frequency Range: 9 kHz to 3.6 GHz
    • Level
      • Max RF level (CW):
          • RF attenuation ≥ 10 dB; RF preamplifier off: 30 dBm (= 1 W)
          • RF attenuation ≥ 10 dB; RF preamplifier on: 23 dBm (= 0.2 W)
      • Max Pulse Voltage:
        • RF attenuation ≥ 10 dB:
            • Input 1: 150 V
            • Input 2: 450 V
      • Max Pulse Energy:
        • RF attenuation ≥ 10 dB; 10 μs
            • Input 1: 1 mWs
            • Input 2: 20 mWs
      • 1 dB Compression:
          • RF attenuation 0 dB; RF preamplifier and preselection off: +3 dBm, nominal
    • IF and Resolution Bandwidths
        • Analyzer Mode (span ≥ 10 Hz) and Receiver Mode: 10 Hz to 10 MHz (–3 dB) in 1/2/3/5/10 steps
        • Analyzer and Receiver Mode: 200 Hz, 9 kHz, 120 kHz (–6 dB), 1 MHz (impulse bandwidth)
      • Preselection:
          • Switchable in analyzer mode: 16 Fixed Filters
      • Preamplifier:
          • Switchable on/off: 1 kHz to 7 GHz, 20 dB gain, nominal
      • Measurement Time:
        • Analyzer Mode (Sweep Time):
            • span = 0 Hz: 1 μs to 16,000 s
            • span ≥ 10 Hz (swept): 1 ms to 16,000 s
            • span ≥ 10 Hz (FFT): 7 μs to 16,000 s
          • Receiver Mode (Stepped Frequency Scan): 50 μs to 100 s (per frequency)
          • Receiver Mode (Time Domain Scan): 50 μs to 100 s (per frequency subrange)
      • Frequency Step Size:
          • Receiver Mode (Stepped Frequency Scan): min. 1 Hz
          • Receiver Mode (Time Domain Scan): 0.25 × IF bandwidth
    • Detectors
      • Receiver Mode:
          • Maximum peak
          • Minimum peak
          • Quasi-peak
          • RMS
          • Average
          • Average with meter time constant (CISPR average)
          • RMS average (CISPR-RMS)
    • Displayed Average Noise Level (DANL)
      • Receiver Mode, Nominal, Average Detector (AV), RF Attenuation 0 dB, Termination 50 Ω:
        • Preamplifier Off:
            • 500 MHz, bandwidth 120 kHz: < 6 dBμV
            • 3 GHz, bandwidth 1 MHz: < 17 dBμV
        • Preamplifier On:
            • 500 MHz, bandwidth 120 kHz: < –7 dBμV
            • 3 GHz, bandwidth 1 MHz: < 5 dBμV
    • Number of Sweep (Trace) Points
        • Analyzer Mode (Standard): 101 to 32,001
        • Analyzer Mode (EMI): 101 to 200,001
        • Receiver Mode: Max 4,000,000
        • Realtime Analyzer (Option): 801
    • Total Measurement Uncertainty
      • CW signal, level 0 dB to –70 dB below reference level, S/N > 20 dB, auto sweep time, RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, preselection on:
          • 9 kHz ≤ f < 3.6 GHz: 0.46 dB
          • 3.6 GHz ≤ f ≤ 7 GHz: 0.57 dB

How can we help you with today?

RECENTLY VIEWED