The R&S ESR7 EMI Test Receiver stands out as an advanced dual-purpose instrument, expertly designed to measure electromagnetic disturbances while also serving as a comprehensive signal and spectrum analyzer tailored for laboratory applications. Experience rapid measurements with its FFT-based time domain scanning capabilities, and delve deeper into disturbance signals through detailed real-time spectrum analysis. The intuitive touchscreen interface and straightforward display enhance user experience, making this compact and robust instrument ideal for both stationary and mobile applications.

Key Features and Specifications of the R&S ESR7 EMI Test Receiver:

  • Features
      • Combines EMI test receiver and signal/spectrum analyzer functionalities in one device.
      • Meets CISPR 16-1-1 Ed. 3.1 compliance standards.
      • Includes preselection with a built-in 20 dB preamplifier for enhanced signal clarity.
      • Offers ultra-fast time domain scans alongside traditional stepped frequency scans.
      • Realtime spectrum analysis capabilities with a span of up to 40 MHz for thorough investigation of disturbance signals.
      • Robust measurement and analysis functions across both frequency and time domains.
      • High-resolution time domain display with a 50 µs resolution.
      • Automated test routines streamline complex testing processes.
      • User-friendly with an intuitive display for effortless operation.
      • Compact design suitable for portable use in various environments.
  • Specifications
    • Frequency:
        • Frequency Range: 9 kHz to 7 GHz
    • Level:
      • Maximum RF level (CW):
          • For RF attenuation ≥ 10 dB; with RF preamplifier off: 30 dBm (= 1 W)
          • For RF attenuation ≥ 10 dB; with RF preamplifier on: 23 dBm (= 0.2 W)
      • Maximum Pulse Voltage:
        • For RF attenuation ≥ 10 dB:
            • Input 1: 150 V
            • Input 2: 450 V
      • Maximum Pulse Energy:
        • For RF attenuation ≥ 10 dB; 10 µs
            • Input 1: 1 mWs
            • Input 2: 20 mWs
      • 1 dB Compression:
          • For RF attenuation 0 dB; without RF preamplifier and preselection: +3 dBm, nominal
    • IF and Resolution Bandwidths:
        • Analyzer Mode (span ≥ 10 Hz) and Receiver Mode: 10 Hz to 10 MHz (–3 dB) in 1/2/3/5/10 steps.
        • Analyzer and Receiver Mode: 200 Hz, 9 kHz, 120 kHz (–6 dB), 1 MHz (impulse bandwidth).
      • Preselection:
          • Can be switched off in analyzer mode with 16 fixed filters.
      • Preamplifier:
          • Can be switched on/off: Covers 1 kHz to 7 GHz, with 20 dB nominal gain.
      • Measurement Time:
        • Analyzer Mode (Sweep Time):
            • span = 0 Hz: 1 µs to 16,000 s
            • span ≥ 10 Hz (swept): 1 ms to 16,000 s
            • span ≥ 10 Hz (FFT): 7 µs to 16,000 s
          • Receiver Mode (Stepped Frequency Scan): 50 µs to 100 s (per frequency).
          • Receiver Mode (Time Domain Scan): 50 µs to 100 s (per frequency subrange).
      • Frequency Step Size:
          • Receiver Mode (Stepped Frequency Scan): minimum 1 Hz.
          • Receiver Mode (Time Domain Scan): 0.25 times IF bandwidth.
    • Detectors:
      • Receiver Mode:
          • maximum peak
          • minimum peak
          • quasi-peak
          • RMS
          • average
          • average with meter time constant (CISPR average)
          • RMS average (CISPR-RMS)
    • Displayed Average Noise Level (DANL):
      • Receiver Mode, nominal, average detector (AV), RF attenuation 0 dB, termination 50 Ω:
        • Preamplifier Off:
            • 500 MHz, bandwidth 120 kHz: < 6 dBµV
            • 3 GHz, bandwidth 1 MHz: < 17 dBµV
        • Preamplifier On:
            • 500 MHz, bandwidth 120 kHz: < –7 dBµV
            • 3 GHz, bandwidth 1 MHz: < 5 dBµV
    • Number of Sweep (Trace) Points:
        • Analyzer Mode (Standard): 101 to 32,001.
        • Analyzer Mode (EMI): 101 to 200,001.
        • Receiver Mode: Maximum 4,000,000.
        • Realtime Analyzer (Option): 801.
    • Total Measurement Uncertainty:
      • CW signal, level 0 dB to –70 dB below reference level, S/N > 20 dB, auto sweep time, RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, preselection on, span/RBW < 100, 95% confidence level, +200C to +300C:
          • 9 kHz ≤ f < 3.6 GHz: 0.46 dB
          • 3.6 GHz ≤ f ≤ 7 GHz: 0.57 dB