Sorensen SGI600-42 DC Power Supply, 600V, 42A, 25kW

Do you have a Sorensen SGI600-42 DC Power Supply, 600V, 42A, 25kW you want to sell?

We buy used equipment! Learn about selling

Image Coming Soon

RENT Sorensen SGI600-42 (call for availability)

The Sorensen SGI600-42 is an advanced Programmable Precision High Power DC Power Supply designed to meet the demands of rigorous testing environments. With exceptional load transient response, low noise levels, and high power density, this unit is ideal for applications requiring reliability and precision. Its stylish front air intake allows for stacked configurations, maximizing space efficiency without sacrificing performance.

Key Features:

    • High Power Density: 25kW within a compact 6U chassis.
    • Wide Voltage Range: 0-600V output with a maximum current of 0-42 Amps.
    • Fast Load Transient Response: Offers protection against undesired voltage fluctuations.
    • Low RMS and P-P Noise: Tailored for sensitive applications requiring minimal noise interference.
    • Expandable Capacity: Capable of parallel operation, allowing for expansion up to 150 kW.
    • Modular Design: Provides the ultimate in upgradeability and investment protection.
    • Custom Sequencing: Program and loop custom waveforms for repetitive testing tasks.
    • Multi-Language Display: Vacuum fluorescent graphical display supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean.
    • Comprehensive Control Options: 16-bit resolution with optional IEEE-488.2 + RS-232C + Ethernet interfaces for precise control.
    • Ethernet Communication: LXI Class C compliant with built-in web server for remote management.
    • Relay Control Features: Includes options for output, sense isolation, and polarity relays (Ethernet Option only).
    • Hardware Trigger Functionality: Available with the Ethernet option for enhanced synchronization.

Specifications:

    • Remote Sense: Load-line loss compensation for models <= 100V is 10% above full scale voltage total; for models > 100V, it is 4% above full scale voltage total.
    • Parallel Operation: Up to 5 units can be paralleled for increased current capability; additional units may add a 0.3% inaccuracy.
    • Series Operation: Capable of connection with up to 2 units.
    • Input Voltage: 3-phase, 3-wire + ground; options include 208/220 VAC (operating range: 187-242 VAC), 380/400 VAC (operating range: 342-440 VAC), and 440/480 VAC (operating range: 396-528 VAC).
    • Frequency: 47-63 Hz (optional 400Hz @ 208VAC, CE, UL, and CSA markings not applicable).
    • Power Factor: Greater than 0.9 at 208/220 VAC input; greater than 0.78 at 380/400 VAC input; greater than 0.69 at 440/480 VAC input.
    • Protection Features: Includes half-cycle ride-though on all three phases and missing phase shutdown capabilities.

Environmental Characteristics:

    • Operating Temperature: 0 to 50°C
    • Storage Temperature: -25°C to 65°C
    • Humidity Range: Up to 95% relative humidity, non-condensing, from 0°C to 50°C.
    • Altitude: Full power available up to 5,000 ft; derate by 10% for every additional 1,000 ft.
    • Cooling System: Front and side air inlet with a rear exhaust; temperature-controlled variable speed fans; units stackable without clearance.
    • Regulatory Compliance: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE compliant, Semi-F47 compliant.
    • Dust Filter: Front panel features a 30 PPI filter to ensure adequate airflow.

Physical Dimensions:

    • Dimensions: Width: 19.00” (48.3 cm), Depth: 25.0” (63.5 cm); 3U units height: 5.25” (13.34 cm), 6U units height: 10.5” (26.67 cm).
    • Weight: 3U units weigh less than 80 lbs. (36 kg).

Output Performance:

    • Ripple & Noise: Specified during full-load, nominal AC input.
    • DC Voltage Slew Rate: 45A/ms typical with resistive load.
    • Efficiency: Approximately 87% at nominal line and maximum load.
    • Load Regulation: ±0.02% of full scale voltage in voltage mode and ±0.1% in current mode.
    • Temperature Coefficient: 0.02%/°C for voltage, 0.03%/°C for current.

Programming and Monitoring:

    • Voltage and Current Accuracy: ±0.1% and ±0.4% of full scale, respectively.
    • Remote Interface Options: Support for analog and digital interfaces, each with specified accuracy and resolution.
    • User I/O Capabilities: Available relay controls for disconnect and polarity-reversal (Ethernet option).