Tektronix TCP312 Current Probe, AC/DC, DC to 100 MHz, 30 A DC

Do you have a Tektronix TCP312 Current Probe, AC/DC, DC to 100 MHz, 30 A DC you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Tektronix

Category: Oscilloscopes Other

Image Coming Soon

Tektronix TCP312 Current Probe

The Tektronix TCP312 Current Probe is a specialized split-core probe that seamlessly combines transformer and Hall effect technologies. Ideal for use with Tektronix oscilloscopes equipped with TEKPROBE Level II, TekConnect (with TCA-BNC), or TekVPI (with TPA-BNC) interfaces, this probe simplifies current measurements and calculations, making it a must-have tool for professionals in various fields.

Features and Specifications of the TCP312 Current Probe

  • Key Features:
      • AC/DC measurement capabilities
      • Trouble-free automatic scaling and unit conversion, requiring a compatible TDS TEKPROBE oscilloscope or TekConnect oscilloscope with TCA-BNC.
      • On-screen readouts display magnitude and amps, eliminating manual calculations for enhanced accuracy.
      • AC/DC input coupling for versatile application.
      • Low insertion impedance reduces loading on the device under test (DUT).
      • Split-core design facilitates effortless circuit connections.
      • Status Indicators provide visual cues for operating conditions, alerting users to potential issues such as:
        • Degauss
        • Probe open
        • Overload
        • Not terminated into 50 Ω
        • Noncompatible probe type
      • Reduced DC drift and noise for improved low-level current measurements.
      • Compliant with IEC standards, ensuring reliability and safety.
  • Applications:
      • Ideal for development and analysis in sectors including Telecomm, Data Comm, semiconductor power electronics, and more, covering:
        • Power supplies (both switching and linear)
        • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
        • Power inverters/converters
        • Electronic ballasts
        • Industrial and consumer electronics
        • Mobile communications (phones, satellites, relay stations)
        • Motor drives
        • Transportation systems (electronic vehicles, trains, avionics)
  • Specifications of TCP312 Probe with TCPA300 Amplifier:
    • Characteristic:
        • Bandwidth (-3 dB): DC - 100 MHz
        • Rise Time: ≤3.5 ns
        • Maximum Current Ratings:
          • High-current Sensitivity Range (10 A/V):
            • DC (Continuous): 30 A
            • RMS (Sinusoidal): 21.2 A
            • Peak Pulse: 50 A
          • Low-current Sensitivity Range (1 A/V):
            • DC (Continuous): 5 A
            • RMS (Sinusoidal): 3.5 A
            • Peak Pulse: 50 A
        • DC Accuracy (Operating Temp: 0 °C to 50 °C): ±3% of reading
        • DC Accuracy, Typical (Operating Temp: 23 °C ±5 °C): ±1% of reading
    • Nominal:
        • Maximum Bare Wire Voltage: For use with insulated wires only
        • Lowest Measurable Current (±3% Accuracy at DC): 1 mA (scope set to 1 mV/div and 20 MHz BW limited)
        • Insertion Impedance:
          • 0.08 Ω at 1 MHz
          • 0.15 Ω at 10 MHz
          • 0.27 Ω at 50 MHz
          • 0.7 Ω at 100 MHz
    • Typical:
        • Maximum Amp-Second Product:
          • 50 AμS – 1 A/V
          • 500 AμS – 10 A/V
        • AC-Coupling Low-frequency Bandwidth (Low Pass – 3 dB point)
        • Displayed RMS Noise (at 20 MHz bandwidth limit): ≤250 mARMS
        • Signal Delay (Delay to Output BNC): 17 ns
        • Probe Amplifier Inputs: 1
        • Probe Open Indicator: Yes
        • Overload Indicator: Yes
        • Termination Indicator: Yes
        • Noncompatible Probe Indicator: Yes