Teledyne LeCroy ZD200 Differential Probe, 200 MHz, 3.5 pF, 1MOhm

Do you have a Teledyne LeCroy ZD200 Differential Probe, 200 MHz, 3.5 pF, 1MOhm you want to sell?

We buy used equipment! Learn about selling

Manufactured by: Teledyne LeCroy

Category: Oscilloscopes Other

Image Coming Soon

TELEDYNE LECROY ZD200

Experience unparalleled performance with the Teledyne LeCroy ZD200 differential probe, expertly designed for demanding electronic testing environments. This advanced probe combines exceptional noise handling and loading performance, offering a comprehensive selection of probe tips, leads, and ground accessories to accommodate a multitude of probing scenarios. With a dynamic input range of ±20 V and a common mode range of ±60 V, the ZD200 is engineered to facilitate a broad array of measurement applications.

Utilizing the innovative ProBus interface, the Teledyne LeCroy ZD200 seamlessly integrates with digital oscilloscopes, providing automatic optimization of probe sensitivity and offset based on oscilloscope gain settings. This feature ensures that users can focus on their measurements without the hassle of manual adjustments. Notably, when paired with a compatible Teledyne LeCroy oscilloscope, the ZD200 operates without the need for any external power supply, adding to its convenience and ease of use.

In scenarios where engineers must navigate tight spaces to access various test points, the ZD200 rises to the occasion with a wide assortment of standard and optional tip accessories. These accessories are meticulously crafted to maintain signal integrity, even in conditions requiring longer leads or additional probing components. Say goodbye to the struggles of reduced bandwidth, increased capacitance, and added noise—thanks to the thoughtfully designed ZD200 accessories, optimal signal fidelity is preserved.

Teledyne LeCroy ZD200 Key Features and Specifications:

    • Bandwidth: 200 MHz
    • Input Resistance: 1 MΩ
    • Rise Time (10–90%): 75 ns (Typical)
    • Probe Attenuation (Nominal): 10x
    • LF Attenuation Accuracy (Warranted): 1%
    • Input Offset (Typical): < 2 mV
    • Probe Only Noise (Typical): 3 mVrms
    • Input Differential Range (Nominal): ± 20 V
    • Common Mode Range (Nominal): ± 60 V
    • CMRR (Typical): 80 dB @ 60 Hz; 50 dB @ 10 MHz
  • DC Input Resistance (Nominal):
      • 250 kΩ (Common Mode)
      • 1 MΩ (Differential Mode)
    • Input Capacitance (Differential) (Typical): 3.5 pF

How can we help you with today?

RECENTLY VIEWED