Teseq (Schaffner) NSG4070 Conducted RF Immunity Test System

Do you have a Teseq (Schaffner) NSG4070 Conducted RF Immunity Test System you want to sell?

We buy used equipment! Learn about selling

Image Coming Soon

RENT Teseq NSG 4070 Conducted RF Immunity Test System

The Teseq NSG 4070, the cutting-edge successor to the NSG 2070, is a versatile EMC immunity test system designed for comprehensive testing and validation across a broad spectrum of applications. With an impressive frequency range of 9 kHz to 1 GHz, the NSG 4070 supports diverse testing requirements, including compliance with IEC 61000-4-6, BCI applications, and as a signal generator and power meter for IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21, among others. Its modular design and capability to utilize internal or external amplifiers ensure maximum flexibility in varied operational environments.

Key Features:

    • Integrated signal generator covering 9 kHz to 1 GHz for precise control
    • Three power meter inputs, compatible within the same frequency range
    • Inbuilt power amplifier module designed for multiple applications
    • Flexible EUT (Equipment Under Test) monitoring options for enhanced analysis
    • Navigation made easy with a 5.7-inch TFT color display
    • Internal, menu-driven control software for seamless operation
    • Basic remote control software alongside a report generator included

Specifications:

Generator:

  • RF
      • Frequency Range: 9 kHz – 1 GHz
      • Resolution: 1 Hz
      • Reference Frequency Output: 10 MHz
  • RF Level
      • Level Range: -60 dBm to +10 dBm
      • Resolution: 0.1 dB
      • Settling Time: 10 ms
  • Amplitude Modulation
      • Modulation Depth: 0 – 100%
      • Modulation Frequency Range: 1 Hz – 50 kHz
  • Pulse Modulation
      • Rise/Fall Time (10% / 90%): < 1 µs
      • Duty Cycle: 10% to 90%
  • External Modulation
      • Delay Time: < 1 µs / 180°
      • Period: Minimum 20 µs
      • Pulse Width: Minimum 10 µs

Power Meter:

    • Frequency Range: 9 kHz – 1 GHz
  • Linear Measurement Range:
      • Channel 1: -15 dBm to +27 dBm
      • Channel 2 & 3: -25 dBm to +20 dBm
    • Maximum Input/No Damage: All channels: +28 dBm
    • Noise Level: >6 dB below measurement range
    • Input Return Loss: >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
    • Connector Type: BNC socket, 50 Ω
  • Accuracy:
      • Channel 1: Typ. channel 1, below 10 MHz: range >25 dBm
      • Channel 2 & 3: Typ. below 10 MHz: range >17 dBm

Power Amplifier (75 Watt Version):

    • Frequency Range: 150 kHz - 230 MHz
    • Input & Output Impedance: 50 Ω
    • Input Return Loss: Min. 10 dB
    • Output Return Loss: Nominal Min. 9.5 dB, 0 dB without damage
    • Gain: Min. 50 dB
    • Gain Flatness: Max. +/- 3 dB
    • Saturated Output Power: Min. 48.75 dBm
    • Max. Input Power Linear Without Damage: < -3 dBm Max. +10 dBm
  • Harmonic Distortion:
      • 2nd: Typ. < -35 dBc
      • 3rd: Typ. < -18 dBc

How can we help you with today?

RECENTLY VIEWED