RENT Teseq NSG 4070 Conducted RF Immunity Test System
The Teseq NSG 4070, the cutting-edge successor to the NSG 2070, is a versatile EMC immunity test system designed for comprehensive testing and validation across a broad spectrum of applications. With an impressive frequency range of 9 kHz to 1 GHz, the NSG 4070 supports diverse testing requirements, including compliance with IEC 61000-4-6, BCI applications, and as a signal generator and power meter for IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21, among others. Its modular design and capability to utilize internal or external amplifiers ensure maximum flexibility in varied operational environments.
Key Features:
- Integrated signal generator covering 9 kHz to 1 GHz for precise control
- Three power meter inputs, compatible within the same frequency range
- Inbuilt power amplifier module designed for multiple applications
- Flexible EUT (Equipment Under Test) monitoring options for enhanced analysis
- Navigation made easy with a 5.7-inch TFT color display
- Internal, menu-driven control software for seamless operation
- Basic remote control software alongside a report generator included
Specifications:
Generator:
- RF
- Frequency Range: 9 kHz – 1 GHz
- Reference Frequency Output: 10 MHz
- RF Level
- Level Range: -60 dBm to +10 dBm
- Amplitude Modulation
- Modulation Depth: 0 – 100%
- Modulation Frequency Range: 1 Hz – 50 kHz
- Pulse Modulation
- Rise/Fall Time (10% / 90%): < 1 µs
- External Modulation
- Delay Time: < 1 µs / 180°
- Pulse Width: Minimum 10 µs
Power Meter:
- Frequency Range: 9 kHz – 1 GHz
- Linear Measurement Range:
- Channel 1: -15 dBm to +27 dBm
- Channel 2 & 3: -25 dBm to +20 dBm
- Maximum Input/No Damage: All channels: +28 dBm
- Noise Level: >6 dB below measurement range
- Input Return Loss: >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
- Connector Type: BNC socket, 50 Ω
- Accuracy:
- Channel 1: Typ. channel 1, below 10 MHz: range >25 dBm
- Channel 2 & 3: Typ. below 10 MHz: range >17 dBm
Power Amplifier (75 Watt Version):
- Frequency Range: 150 kHz - 230 MHz
- Input & Output Impedance: 50 Ω
- Input Return Loss: Min. 10 dB
- Output Return Loss: Nominal Min. 9.5 dB, 0 dB without damage
- Gain Flatness: Max. +/- 3 dB
- Saturated Output Power: Min. 48.75 dBm
- Max. Input Power Linear Without Damage: < -3 dBm Max. +10 dBm
- Harmonic Distortion: