Xantrex XDC60-200 Programmable Power Supply
The Xantrex XDC60-200 Power Supply stands out as a premier choice in programmable DC power supply technology, delivering remarkable versatility and performance for various applications including Automatic Test Equipment (ATE), production testing, burn-in, bulk power, and OEM needs.
Key Features
With a maximum output voltage of 60V, current of 200A, and power capacity of 12kW, this power supply is designed to meet demanding requirements. The embedded controller enhances user experience with its unique menu-driven auto sequencing capability, allowing for the entry and saving of complex test sequences directly from the front panel, eliminating the need for external computers or software.
Programmable Testing
The XDC60-200 supports up to ten different test programs, each offering 99 voltage level steps that can vary from milliseconds to days. Users can execute programs via manual or external triggers, or integrate them with a computer interface. The device allows a technician to single step through sequences, repeat tests, or run them continuously based on front panel or remote triggers, making it ideal for:
- Battery voltage simulation during engine start-up
Specifications
Output Ratings
Line Regulation
- Voltage (0.01% of Vmax): 6mV
- Current (0.1% of Imax): 200mA
Load Regulation
- Voltage (0.05% of Vmax + 5 mV): 35mV
- Current (0.2% of Imax + 40 mA): 440mA
Meter Accuracy
- Voltage (0.15% of Vmax): 90mV
- Current (0.5% of Imax): 1mA
Output Noise (0-20 MHz)
Output Ripple (rms)
Drift (30 minutes)
- Voltage (0.04% of Vmax): 24mV
- Current (0.6% of Imax): 1200mA
Drift (8 hours)
- Voltage (0.04% of Vmax): 12mV
- Current (0.6% of Imax): 120mA
Temperature Coefficient
- Voltage (0.04% of Vmax/°C): 24mV
- Current (0.06% of Imax/°C): 120mA
OVP Adjustment Range
- (5% to 103% of Vmax): 0-61.8V
Efficiency:
89%
Standard Features
- Power Factor Correction (PFC)
- Zero voltage “soft switching”
- 16-bit digital processing
- Ten store/recall locations
- 99-step, menu-driven auto sequencing
- Advanced internal programming
- Nine self-protection mechanisms
- Isolated analog programming
- Bright vacuum fluorescent display
- Front panel software-based calibration
- Remote sense with 5 V line loss compensation
- UL, CSA, CE approvals; FCC compliant