Keithley 2303 Power Supply
The Keithley 2303 Power Supply is designed for voltage control and power monitoring tailored for automated testing of portable, battery-operated devices. Boasting an impressive output of up to 5A, the Keithley 2303 efficiently handles demanding portable device loads. Features such as 100nA resolution enable precise monitoring of sleep mode currents, ensuring a 0.2% basic accuracy that is crucial for product reliability.
This power supply simulates battery behavior with its fast transient response, returning to within 100mV of the set output voltage in just 40μs. Furthermore, it can sink current, effectively mimicking the characteristics of a discharged rechargeable battery, making it ideal for testing battery chargers and related circuitry. In addition to providing DC current measurements, the Keithley 2303 excels at measuring current pulses with a range from 60μs to 833ms.
Key Features and Specifications
DC Voltage Output
- Output Voltage: 0 to +15V DC
- Output Accuracy: ±(0.05% + 10mV)
- Programming Resolution: 5mV
- Readback Accuracy: ±(0.05% + 3mV)
- Output Voltage Settling Time: 5ms
- Load Regulation: 0.01% + 2mV
- Transient Response:
- Recovery Time: < 40μs to within 100mV; < 80μs to within 20mV
- Transient Voltage Drop: < 100mV, typical
- Ripple and Noise (20Hz to 20MHz): 3mV rms/8mV p-p, typical
DC Current
- Output Current: 0–9V: 5A max; >9V–15V: 3A max
- Source Compliance Accuracy: ±(0.16% + 5mA)
- Programmed Source Compliance Resolution: 1.25mA
- Readback Accuracy:
- 5A range: ±(0.2% + 400μA)
- Readback Resolution:
- Current Sink Capacity: 0–5V: 2A max; 5V–15V: Derate 0.1A per volt above 5V
- Load Regulation: 0.01% + 1mA
Digital Voltmeter Input
- Input Voltage Range: 0 to +20V DC
- Input Impedance: 10^10Ω typical
- Maximum Voltage: –3V, +22V with respect to output low
- Reading Accuracy: ±(0.05% + 3mV)
DC General
- Measurement Time Choices: 0.01 to 10 PLC, in 0.01PLC steps
- Average Readings: 1 to 10
- Reading Time: 31ms, typical
Pulse Current Measurement Operation
- Trigger Level: 5mA to 5A, in 5mA steps
- Trigger Delay: 0 to 100ms, in 10μs steps
- Internal Trigger Delay: 25μs
- High/Low/Average Mode:
- Measurement Aperture Settings: 33.3μs to 833ms, in 33.3μs steps
- Average Readings: 1 to 100
- Burst Mode:
- Measurement Aperture: 33.3μs
- Conversion Rate: 3600/second, typical
- Number of Samples: 1 to 5000
- Transfer Samples Across IEEE Bus in Binary Mode: 4800 bytes/second, typical
- Long Integration Mode:
- Measurement Time: 850ms (840ms) to 60 seconds in 16.7ms (20ms) steps
Explore Other Models in This Series
- Keithley 2304 High Speed Precision Power Supply
- Keithley 2304A High Speed Precision Power Supply