Keysight / Agilent 81133A Pulse Pattern Generator
The Keysight 81133A Pulse Pattern Generator is designed for advanced hardware-based PRBS and memory-based pattern generation, ideal for testing high-speed digital interfaces. With basic test patterns tailored for Infiniband, PCI-Express, and Serial ATA, this generator accommodates a variety of applications and requirements.
Key Features
- High-speed applications with low intrinsic jitter for accurate signal testing
- Fast rise times (< 60 ps) enhance data signal characterization
- Robust 12 Mbit pattern memory ensures reliable long data stream handling, perfect for disk drive tests
- Ability to distort clock and data signals for comprehensive signal integrity tests
- Variable cross-point and jitter insertion capabilities simulate real-world conditions
- User-friendly graphical interface for easy access to critical parameters
- Control through GPIB, LAN, and USB 2.0 for ease of integration
- SMA connectors facilitate differential outputs for maximum flexibility
Specifications
Internal Clock Generation
- Period Range: 298.5 ps - 66.6 ns
- Frequency Range: 15 MHz - 3.35 GHz
- Period Resolution: 0.001 ps (6 digits best case)
- Frequency Resolution: 1 Hz
Jitter Characteristics
- Random Jitter (Clock Mode)
Channel Output Timing
- Transition Times: 10%-90% < 90 ps; 20%-80% < 60 ps
- Delay Variation: -5 ns to 230 ns; Delay Resolution: 1 ps
- Phase: -6000° to +279000° with 0.01° resolution
- Skew Between Differential Outputs: < 20 ps nominal
- Width Range: 100 ps to (period - 100 ps); Width Accuracy: ±40 ps
Channel Output Levels
- Amplitude: 50 mV to 2.00 V; Level Window: -2.00 to +3.00 V
- Level Resolution: 10 mV; Level Accuracy: 2% of setting + 20 mV
- Impedance: 50 Ω nominal; Overshoot, Ringing: < 10% + 10 mV
- Short Circuit Current: -80 mA < Isc ≤ 120 mA nominal
- Normal / Complement: Selectable
Data Generation
- Memory Depth: 12 Mbit extended memory, 8 Kbit per channel
- Supported Data Formats: RZ, NRZ, RI
Trigger Output
- Amplitude: 50 mV to 2.00 V; Fixed Duty Cycle: 50% nominal
- Transition Times (20% to 80% of amplitude): < 100 ps
- Maximum External Voltage: -2.00 V to +3.00 V
Delay Control Input
- Interface: DC-coupled; Input Levels for full Modulation Range: +500 mV to +2.5 V
- Delay Modulation Range: ±250 ps with selectable modulation frequency (0 Hz - 200 MHz)
Clock Input
- Interface: AC-coupled with optional DC termination; Minimum Amplitude: 300 mV
- Frequency Measurement: Yes; Frequency Measurement Accuracy: 50 ppm
- Period Range: 299 ps – 66.6 ns with 6 digits resolution
For professionals seeking precision in pulse pattern generation, the Keysight 81133A delivers unmatched performance and versatility, essential for today’s fast-paced digital testing environments.