TEKTRONIX TCP305 PROBE
Introducing the Tektronix TCP305 Current Probe, a high-performance split-core probe that integrates both transformer and Hall effect technologies. Designed for seamless connectivity with Tektronix oscilloscopes featuring TEKPROBE Level II, TekConnect (with TCA-BNC), or TekVPI (with TPA-BNC) interfaces, this probe simplifies current measurements and calculations for various applications.
Key Features and Specifications of the TCP305 Current Probe:
- Features:
- Comprehensive AC/DC measurement capabilities
- Automatic Scaling and Units with:
- Compatible with TDS TEKPROBE oscilloscopes or TekConnect oscilloscopes with TCA-BNC
- On-screen oscilloscope readout of magnitude and amps
- Minimized measurement errors, eliminating hand calculations
- AC/DC input coupling for versatile applications
- Low insertion impedance reduces Device Under Test (DUT) loading
- Split-core design for effortless circuit connection
- Status Indicators for real-time feedback on operating conditions, signaling:
- Degauss, Probe open, Overload, Not terminated into 50Ω, Noncompatible probe type
- Improved low-level current measurements with lower DC drift and noise
- Complies with IEC standards for reliable performance
- Applications:
- Ideal for designers, installers, and service personnel in Telecomm, Data Comm, computer, and semiconductor power electronics sectors for:
- Power supplies (both switching and linear)
- Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
- Power Inverters/Converters
- Industrial and Consumer electronics
- Mobile communications (phones, satellites, relay stations)
- Transportation systems (including electronic vehicles, trains, locomotives, avionics)
- Specifications of TCP305 Probe:
- Characteristic:
- Bandwidth (-3 dB): DC - 50 MHz
- Maximum Current Ratings:
- High-current Sensitivity Range: 10 A/V
- Low-current Sensitivity Range: 5 A/V
- DC Accuracy (operating temp 0°C to 50°C): ±3% of reading
- DC Accuracy, typical (operating temp 23°C ±5°C): ±1% of reading
- Nominal:
- Maximum Bare Wire Voltage: Suitable for insulated wires only
- Lowest Measurable Current (±3% accuracy at DC):
- Scope set to 1 mV/div and 20 MHz BW limited
- Insertion Impedance:
- Typical:
- Maximum Amp-Second Product (based on amplifier range setting):
- AC-coupling Low-frequency Bandwidth (Low Pass – 3 dB point):
- Displayed RMS Noise (at 20 MHz bandwidth limit): ≤1.25 mARMS
- Signal Delay (delay to output BNC): 19 ns
- Probe Amplifier Inputs: 1
- Probe Open Indicator: Yes
- Termination Indicator: Yes
- Noncompatible Probe Indicator: Yes